cover
Contact Name
Tri Wahyono
Contact Email
wahyonotri25@gmail.com
Phone
-
Journal Mail Official
hsosiati@gmail.com
Editorial Address
-
Location
Kab. bantul,
Daerah istimewa yogyakarta
INDONESIA
JMPM (Jurnal Material dan Proses Manufaktur)
ISSN : 25803271     EISSN : 26565897     DOI : 10.18196/jmpm
Core Subject : Engineering,
Jurnal Material DAN Proses Manufaktur focuses on the research and research review in the field of engineering material and manufacturing processes. The journal covers various themes namely Design Engineering, Process Optimization, Process Problem Solving, Manufacturing Methods, Process Automation, Material research and investigation, Advanced Materials, Nanomaterials, Mechanical solid and fluid, Energy Harvesting and Renewable Energy.
Arjuna Subject : -
Articles 1 Documents
Search results for , issue "Vol 8, No 2 (2024): DESEMBER" : 1 Documents clear
Evaluation and Identification of Opportunities for Saving Electrical Energy Consumption in Artificial Lighting Systems Inside Buildings
JMPM (Jurnal Material dan Proses Manufaktur) Vol 8, No 2 (2024): DESEMBER
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jmpm.v8i2.22184

Abstract

The artificial lighting system is a major component in a building, consuming up to 50% of its electrical energy. Hence, it is crucial to evaluate and identify opportunities for energy savings. Industries involve numerous operational instruments, one of which is building structures with artificial lighting systems. The requirements for artificial lighting systems consider energy conservation principles aimed at achieving energy consumption efficiency during operation. Therefore, a series of energy management activities and energy conservation evaluations are conducted through an audit of the artificial lighting system in a building with 50 rooms (the study object). The audit method used is the Short Energy Audit (SEA) to calculate Energy Consumption Intensity (ECI) under actual conditions (condition 1) and predictions under improvement conditions (condition 2). The results depict an energy usage portrait (evaluation) showing that 100% of electricity consumption is efficient, with the ECI target standard at 2,5 kWh/m2. The percentage saving (PS) in condition 1 are 68,058% and in condition 2 are 64,967%, indicating that improvements will not significantly alter the energy saving opportunities but will provide considerable benefits in operational investment. Recommendations include making small short-term investments in repairs, maintenance, optimizing lighting system operations, and conducting initial energy audits

Page 1 of 1 | Total Record : 1