Yulkifli Yulkifli
Department of Physics, Universitas Negeri Padang, Padang, Indonesia

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

A Pid Control System Using Ziegler-Nichols Method on Wheeled Soccer Robot Movement System Hanifah Nur Ismail; Yulkifli Yulkifli; Rio Anshari; Dani Harmanto
Research on Instrumentation Vol. 1 No. 1 (2024): Research on Instrumentation
Publisher : RESSTECH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.66926/rins.2024.7

Abstract

The rapid advancement of robotics has impacted various sectors, including education. The Indonesian Robot Contest (KRI), organized by the Indonesian Talent Development Center, serves as a platform for innovation, featuring events like the Wheeled Indonesian Soccer Robot Contest (KRSBI-B). This study focuses on implementing a PID control system on a PG 45 type DC motor in a wheeled soccer robot, utilizing the Ziegler-Nichols method to determine optimal PID parameters. The goal is to design a stable PID control system and analyze how Kp, Ki, and Kd parameters influence robot movement. The research employs a scientific, rational, empirical, and systematic approach, using the Ziegler-Nichols method in quantitative research. The results demonstrate the successful design and implementation of the PID control system on the PG45 DC motor, with a rotary encoder used for RPM output and three-wheel kinematics for varied movements. While the Kp, Ki, and Kd values were optimal in motor tests without a load, some values failed to reach the setpoint during road tests due to additional motor load. Adjusting Kp, Ki, and Kd significantly affects the robot's movement, enhancing quick error response, reducing constant errors, and improving overshoot responsiveness. Future research should consider the test environment, use additional sensors for better data accuracy, and conduct repeated tests and evaluations to ensure system performance. This study offers practical and theoretical insights for the development of wheeled soccer robots and contributes significantly to future robotics research.
Air Column Length Measurement in a Sound-Wave Resonance Experiment Using HC-SR04 Ultrasonic Sensor Rahmadina Fitri; Yulkifli Yulkifli; Mona Berlian Sari
Research on Instrumentation Vol. 3 No. 2 (2026): Research on Instrumentation
Publisher : RESSTECH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.66926/rins.2026.2.60

Abstract

This study evaluates the performance of the HC-SR04 ultrasonic sensor for measuring air column length in a sound-wave resonance experiment at 512 Hz. The sensor's accuracy and precision were assessed through comparison with a ruler as a reference instrument and repeated measurements. The characterization results show excellent linearity with R² = 0.99822. The accuracy test results show an average error of 1.156% and accuracy of 98.85%. The precision test at 10 cm yielded an average precision of 96.19%, while the precision test at 512 Hz (first resonance order) produced an average precision of 98.02%. In the resonance experiment at 512 Hz, the sensor was applied to measure air column lengths at the first, second, and third resonance orders. The measured values were compared with theoretical calculations, yielding an average accuracy of 98.26%. The measurements were conducted in an air-conditioned laboratory at 20 °C. Therefore, the results should be interpreted within the tested experimental conditions and the limitations of the measurement conditions.