Performance degradation analysis of induction motors using Simulink and hybrid method Kamrai Janprom; Sittadach Morkmechai; Natchanun Prainetr; Supachai Prainetr
International Journal of Applied Power Engineering (IJAPE) Vol 15, No 2: June 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijape.v15.i2.pp525-534

Abstract

Voltage unbalance faults (VUF) have a significant adverse impact on the performance and operational lifespan of induction motors. This paper presents a hybrid method that integrates multi-sensor analysis to evaluate induction motor behavior under different levels of electrical fault conditions. The research methodology comprises the development of a three-phase induction motor model in MATLAB/Simulink, combined with experimental monitoring of current, voltage, rotational speed, acoustic signals, and torque. The collected data are analyzed using linear regression to quantify performance degradation. The results indicate that increasing fault severity correlates with reductions in motor efficiency and operational stability. Furthermore, a hybrid technique incorporating modulation analysis of acoustic signals derived from vibration and resonance is proposed to improve the accuracy of efficiency and loss estimation. This approach outperforms conventional methods and demonstrates strong potential for industrial applications, as it effectively mitigates the negative effects of voltage supply faults.
Condition assessment of medium voltage cable insulation using leakage current and phase-resolved partial discharge Kamrai Janprom; Sittadach Morkmechai; Natchanun Prainetr; Supachai Prainetr
International Journal of Applied Power Engineering (IJAPE) Vol 15, No 3: September 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijape.v15.i3.pp1340-1350

Abstract

Reliable operation of medium-voltage distribution networks critically depends on the integrity of cross-linked polyethylene (XLPE) insulated cables. This paper proposes a diagnostic methodology that integrates leakage current (LC) measurement with phase-resolved partial discharge (PRPD) analysis to assess cable insulation condition. A MATLAB R2025 simulation model is first developed to emulate partial discharge (PD) signals superimposed on leakage current, providing preliminary validation of the proposed approach. The method is then experimentally verified using a 70 mm² XLPE cable rated at 16/20 (24) kV and tested in accordance with IEC 60502. Under applied high-voltage stress, leakage current and PD activity are measured, and insulation degradation is characterized using PRPD patterns. Both simulation and experimental results confirm that the proposed method reliably detects insulation defects and provides accurate condition assessment of XLPE cables. These findings demonstrate the potential of the method as a practical tool for supporting condition-based maintenance in medium-voltage power distribution systems.