Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analysis of Patterns and Drag of Tandem Minibus Models in Various Configurations Wawan Rauf; Rahmad Hidayat Boli; Sahional Ishak; Novriyanti Talango
Engineering Science Letter Vol. 5 No. 01 (2026): Engineering Science Letter
Publisher : The Indonesian Institute of Science and Technology Research

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56741/IISTR.esl.001961

Abstract

The flow through three mini buses arranged in tandem is one type of fluid flow in infrastructure and transportation engineering. The characteristics of the flow pattern formed in each vehicle have an influence on the flow pattern formed in other vehicles. The purpose of this study is to analyze the drag coefficient and characteristics of the flow pattern in models in various configurations and distances between models. The test was conducted by applying experimental methods and numerical computation to obtain the characteristics of the flow pattern. Specifically, to obtain the results of the drag coefficient, the method used was only numerical computation. The results of the study showed that the distance between the M/D models influenced the flow pattern formed in all configurations. The smallest drag coefficient for each Configuration 1 (Cd = 1.43285 at M/D = 0.03), Configuration 2 (Cd = 0.80341 at M/D = 0.01), and Configuration 3 (Cd = 0.77911 at M/D = 0.03), as well as the model with the lowest drag compared to all distances in Configuration 1 and Configuration 2.
Enhancement of Solar Panel Efficiency by Comparative Analysis of Cooling Systems Utilizing Water Flow, Air Flow, and No Cooling Rifaldo Pido; Rahmad Hidayat Boli; Randy Rianto Day
Journal of Mechanical Engineering, Science, and Innovation Vol 5, No 1 (2025): (April)
Publisher : Institut Teknologi Adhi Tama Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31284/j.jmesi.2025.v5i1.7336

Abstract

This paper presents the results of a study on increasing the efficiency of solar panels with a comparative analysis of cooling systems utilizing air flow, air and without cooling. The method with cooling flow is used to absorb heat generated by the PV module. This study was designed simply and effectively, tested in outdoor conditions. The rear surface of the PV panel was flowed with a fluid that was in direct contact. The results showed that solar panels with air cooling systems were relatively more effective compared to other cooling systems, namely being able to increase output power by 36.50 watts and efficiency by 12.7%, compared to air cooling systems with output power of 34.56 watts and efficiency of 11.12%, while for solar panels without cooling the output power was 31.01 watts and efficiency of 10.56%.