Claim Missing Document
Check
Articles

Found 2 Documents
Search

Pengaruh Variasi Tinggi Bukaan Pintu Sorong Terhadap Bilangan Froude Dengan Material Pasir Sungai Dopi di Saluran Terbuka Irnovia Berliana Pakpahan; Ni Made Linda; sri susilawati
SIPARSTIKA: Jurnal Ilmiah Ilmu-Ilmu Teknik Vol. 5 No. 2 (2026): SIPARSTIKA : Jurnal Ilmiah Ilmu-Ilmu Teknik
Publisher : Fakultas Teknik Universitas Tompotika Luwuk

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55114/siparstika.v5i2.1393

Abstract

A sluice gate is a hydraulic control structure that functions to regulate flow discharge and water surface elevation in both the upstream and downstream sections of a hydraulic system. However, areas adjacent to the gate are highly susceptible to scour processes occurring both upstream and downstream of the structure. This study aims to analyze the effect of variations in sluice gate opening height on the Froude number in an open channel using Dopi River sand as the bed material. The research was conducted using an experimental laboratory approach in an open-channel flume. Three sluice gate opening heights (Yg) were investigated: 0.5 cm, 0.7 cm, and 1.0 cm, while maintaining a constant discharge (Q) of 226.231 cm³/s. The experimental results indicate that the sluice gate opening height significantly affects flow velocity. An inverse relationship was observed between gate opening height, flow velocity, and the downstream Froude number. As the gate opening decreases, the flow velocity increases, while the downstream water depth (y₁) becomes shallower. Furthermore, the gate opening height (Yg) influences the Froude number (Fr), where a smaller gate opening results in a higher downstream Froude number and greater scour depth due to the increase in flow velocity. The calculated Froude numbers downstream of the sluice gate for opening heights of 0.5 cm, 0.7 cm, and 1.0 cm were 0.261, 0.255, and 0.207, respectively. These values indicate that the flow regime remained subcritical (Fr < 1) under all tested conditions.
Analisis Persentase Kehilangan Air pada Jaringan Pipa Distribusi PDAM UE Malino Poso Unit Tentena di Kelurahan Petirodongi Irnovia Berliana Pakpahan; Riwan F. Kello; Dinar Mardiana; Yunruth H Marande
Manufaktur: Publikasi Sub Rumpun Ilmu Keteknikan Industri Vol. 4 No. 3 (2026): Manufaktur: Publikasi Sub Rumpun Ilmu Keteknikan Industri
Publisher : Asosiasi Riset Ilmu Teknik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/manufaktur.v4i3.1860

Abstract

Water loss in clean water distribution networks is one of the main challenges faced by Regional Water Utilities (Perusahaan Daerah Air Minum – PDAM) in maintaining efficiency and continuity of water supply to the public. Water loss can also cause financial losses. his study aims to analyze the level of water loss in the drinking water distribution network within the service area of Petirodongi Village, under PDAM UE Malino Poso (Tentena Unit), based on Non-Revenue Water (NRW) and Infrastructure Leakage Index (ILI) indicators. Data collection was based on field surveys and observations, literature studies, as well as primary and secondary data collection. The analytical methods used were the Water Balance calculation and the Infrastructure Leakage Index (ILI) method based on International Water Association (IWA) guidelines. These include four physical water loss classifications suitable for developing countries based on ILI score ranges: category A (1–4), category B (4–8), category C (8–16) and category D (>16). The results showed that water loss from customer water meters due to meter inaccuracy was 4,20% or 8,148 m3/year, the NRW value based on the water balance was 21,571,91 m3/year (11,12%), and the ILI value for an average pressure of 20,66 m was 11,81% (leakage rate of 200-400 liters/connection/day), which falls into category C.