Claim Missing Document
Check
Articles

Found 4 Documents
Search

An Optimized Balanced-Learning Framework for Malignant Skin Lesion Triage Using Compound-Scaled Neural Networks Argha Orion Silitonga; Raissa Camilla Maringka; Wilsen Grivin Mokodaser; George M W Tangka; Marchel Timothy Tombeng
Bulletin of Informatics and Data Science Vol 5, No 1 (2026): May 2026
Publisher : PDSI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61944/bids.v5i1.165

Abstract

Skin cancer represents a prevalent global health challenge, and early detection is very important to reduce mortality risk. Manual dermoscopic diagnosis risks human bias, making deep learning classification a vital research topic. While several previous studies utilizing the ISIC 2019 dataset have demonstrated high diagnostic capabilities, they primarily focus on complex multi-class classification. However, in real-world clinical workflows, the primary necessity is a swift, dependable triage system that can confidently distinguish dangerous lesions from non-threatening ones. Furthermore, many existing models require substantial computational overhead yet still suffer from imbalanced accuracy when dealing with minority malignant classes. The novelty of this study lies in addressing these gaps by developing a streamlined, clinically practical binary screening framework optimized specifically for malignant-versus-benign triage. The original multi-class labels were transformed into binary classes where malignant lesions consist of melanoma (MEL), basal cell carcinoma (BCC), and squamous cell carcinoma (SCC), while benign lesions consist of nevus (NV), benign keratosis (BKL), dermatofibroma (DF), and vascular lesions (VASC). The experiment applied transfer learning with ImageNet-pretrained weights, data augmentation, class weighting, and fourfold stratified cross-validation. Unlike prior works that rely on resource-heavy architectures, we leverage the compound-scaled EfficientNet-B4 backbone—delivering superior feature representational power with significantly fewer parameters evaluate on a large-scale cohort of 25,331 dermoscopic images. Experimental results show that the proposed model achieved an average accuracy of 89.77% and an average ROC AUC of 96.16%. The best fold obtained 91.49% accuracy with ROC AUC of 97.19%. Simultaneously, the framework maintained an average F1-score of 89.20%
Sistem Lost and Found Berbasis Vision-Language Retrieval dengan Explainable AI untuk Lingkungan Smart Campus Enrico Samuel Djimesha; Regi Fernando Najoan; Argha Orion Silitonga; Wilsen Grivin Mokodaser; George Morris William Tangka
Journal of Information System Research (JOSH) Vol 8 No 1 (2026): October 2026
Publisher : Forum Kerjasama Pendidikan Tinggi (FKPT)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47065/josh.v8i1.10990

Abstract

Evidence for combined image-text retrieval in campus lost-and-found systems remains limited, and zero-shot CLIP's ability to distinguish item attributes and identities is uncertain. This study evaluates CLIP ViT-B/32 on an item-image collection covering eight categories. The controlled multimodal evaluation uses 404 images, 85 metadata-defined relevance groups as proxy ground truth, and 237 leave-one-out queries. Separate image-only validation uses 387 images from 79 provenance-based Object IDs after duplicate removal and quality control; each Object ID contains multiple images of the same physical item. In Object-ID validation, CLIP achieved Recall@1 of 0.674, Recall@10 of 0.935, and mAP of 0.419 (95% object-cluster bootstrap CI: 0.369–0.469). In multimodal evaluation, image-only achieved mAP 0.624, text-only 0.409, and image+text reached the best mAP of 0.732 at α=0.5, selected in four of five group cross-validation folds. Ablation showed that the single fused-index outperformed the three-index configuration (mAP 0.715 versus 0.692); therefore, three-index is not claimed as an accuracy improvement. Direct Indonesian input to English CLIP achieved mAP 0.163, compared with 0.363 using multilingual CLIP and 0.409 through translation. Attention Rollout is positioned only as a supporting visualization because its deletion-curve AUC of 0.871 lacks a random-occlusion baseline. These results indicate the benefit of image-text fusion under controlled evaluation but do not establish performance for free-form user descriptions or production readiness.
True Structured Network Surgery of EfficientNet-B3 with Focal Loss for Highly Imbalanced Dermoscopic Image Analysis Argha Orion Silitonga
Journal of Information System Research (JOSH) Vol 8 No 1 (2026): October 2026
Publisher : Forum Kerjasama Pendidikan Tinggi (FKPT)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47065/josh.v8i1.11161

Abstract

Skin tumor classification relies heavily on deep convolutional neural networks, which are computationally expensive for edge deployment. This study proposes a resource-efficient pipeline using true structured network surgery on an EfficientNet-B3 architecture. To address the extreme class imbalance in the ISIC dataset, we implemented minority class oversampling alongside a custom Binary Focal Loss function. Our experiments evaluated 0%, 20%, and 50% structural channel pruning utilizing L2-norm magnitude importance. The baseline model achieved an Area Under the Curve (AUC) of 0.9314 with 10.70 million parameters. At 50% pruning, the parameter footprint dropped by 74% to 2.79 million, and floating-point operations (FLOPs) decreased by 71% to 0.55 G. Despite these reductions, latency metrics indicated a hardware execution plateau on an NVIDIA RTX 3060 Laptop GPU, stabilizing at approximately 12.93 ms per image. By dynamically optimizing the decision threshold using Youden's J statistic, the 50% pruned model maintained a high malignant sensitivity (recall) of 81.59%, despite an overall accuracy reduction to 76.69%. These results demonstrate that combining physical tensor pruning with focal loss yields highly compressed models capable of robust malignant lesion recall. Furthermore, post-hoc visual interpretability via Grad-CAM verified that these compressed architectures retained their clinical diagnostic integrity by accurately localizing genuine pathological features. The primary contributions of this research include the demonstration of true structural channel pruning to reduce model parameters by 74% for edge deployment, the preservation of an 81.59% malignant sensitivity in a highly compressed network using Binary Focal Loss and dynamic thresholding via Youden's J statistic, and the verification of post-pruning diagnostic integrity using Grad-CAM. This pipeline presents a viable pathway for deploying lightweight, accurate dermatological diagnostic tools in resource-constrained clinical environments.
Klasifikasi Hierarkis dengan Kalibrasi Probabilitas untuk Penyakit Daun Singkong Menggunakan Fusi Fitur dan Random Forest Regi Fernando Najoan; Enrico Samuel Djimesha; Argha Orion Silitonga; Wilsen Grivin Mokodaser; George William Tangka
Journal of Information System Research (JOSH) Vol 8 No 1 (2026): October 2026
Publisher : Forum Kerjasama Pendidikan Tinggi (FKPT)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47065/josh.v8i1.11238

Abstract

Field-image classification of cassava leaf disease requires trustworthy probabilities and a mechanism for withholding uncertain decisions, rather than label accuracy alone. This study evaluates HSV, GLCM, and MobileNetV3-Small embedding fusion in a two-stage hierarchical Random Forest with probability calibration and selective prediction. A total of 7,508 CCMT images were evaluated using outer stratified 5-fold cross-validation. Model comparisons report mean ± standard deviation across five outer folds. End-to-end MobileNetV3-Small achieved 93.90±0.73% accuracy, 94.64±0.59% balanced accuracy, and 94.23±0.73% Macro F1, exceeding the Hierarchical Hybrid Random Forest at 88.28±1.12%, 89.66±0.76%, and 88.79±1.07%, respectively. The 1.03-percentage-point Macro F1 difference between the hierarchical and Flat Hybrid models was not significant at the 5% level (two-sided Wilcoxon, p=0.125). A separate calibration and selective-prediction experiment divided each outer-train fold into 70% model-fit, 15% calibrator-fit, and 15% threshold-selection partitions, all disjoint from the outer-test fold. Simplex-temperature yielded the lowest ECE (0.54%), whereas sigmoid performed better on log loss and Brier score. Thresholds selected on the held-out threshold-selection partition yielded 75.87% outer-test coverage, 95.40% accepted accuracy, and 95.58% accepted Macro F1. Selective accuracy applies only to accepted samples, not all data or guaranteed future performance; the contribution is evaluation of the coverage–risk trade-off, not improved intrinsic accuracy.