Cong-Son Pham
Department of Electrical and Mechatronics, Lac Hong University

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

Mathematical model to evaluate the effect of key operating conditions on proton exchange membrane fuel cell performance Tan-Thich Do; Trung-Kien Vi; Cong-Son Pham
International Journal of Renewable Energy Development Vol 15, No 5 (2026): September 2026
Publisher : Center of Biomass & Renewable Energy (CBIORE)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61435/ijred.2026.62184

Abstract

Nowadays, proton exchange membrane fuel cells (PEMFCs) are regarded as a promising energy source for future applications due to their relatively low operating temperature, high efficiency, high power density, fast start-up capability, and zero emissions. During PEMFC operation, performance is influenced by numerous factors, including the key operating conditions. Therefore, developing a mathematical model to evaluate the effects of key operating conditions on PEMFC performance and energy efficiency is both necessary and significant in the PEMFCs. In this study, a mathematical model was developed using MATLAB/Simulink software and subsequently validated through a series of experiments to assess its accuracy. The results demonstrate that PEMFC performance is strongly affected by operating conditions, including operating temperature, operating pressure, membrane thickness, cathode gas type, cell active area, and the number of cells in the stack. In addition, water, heat generation, energy efficiency, and gas consumption were also considered and discussed detailed in the model. The findings indicate that operating temperature and pressure are the most influential parameters affecting PEMFC performance and energy efficiency. When the operating temperature increased, the cell performance improved due to enhanced electrochemical reaction kinetics and improved electrical conductivity. However, when the PEMFC operates at temperatures above 70 oC, a deterioration in performance is observed. This behavior can be attributed to membrane dehydration at elevated temperatures, which reduces proton conductivity and, consequently, lowers the output cell voltage. Increasing pressure reduces membrane resistance and interface contact resistance, leading to a decrease in voltage losses and an improvement in cell voltage. Therefore, the optimal operating tempearature was achieved at 70 oC in this study. At a current density of 0.5 A cm−2, the cell voltages are 0.550, 0.559, 0.564, 0.568, 0.571, and 0.574 V for anode operating pressures of 1.0, 1.5, 2.0, 2.5, 3.0, and 3.5 atm, respectively. Overall, this study provides a reliable and precise tool for predicting PEMFC performance under varying operating conditions.