Temperature response analysis between PD and PI controls applied to infant incubators Abd. Kholiq; Lamidi Lamidi; Farid Amrinsani; Anisia Yunita Maulani Argumery; Hafizh Aushaf Mahdy
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 23, No 2: April 2025
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v23i2.25879

Abstract

Premature infants, born with low birth weight, require specialized care and isolation due to their vulnerability to infections in public settings. Baby incubators, classified as life support equipment, play a crucial role in safeguarding these infants by maintaining a consistent temperature and humidity similar to the mother’s womb. This study compares the temperature control systems in baby incubators, specifically proportional and derivative (PD) control versus proportional and integral (PI) control. LM35 and DS18B20 sensors were employed in the study. Results from PD control using the LM35 sensor show a rise time of 5 min and 40 sec, a settling time of 25 min, and an overshoot of 2.2 °C. The DS18B20 digital sensor, under PD control, achieves a rise time in 6 min and 30 sec, a settling time of 23 min, with an overshoot of 1.2 °C. For PI control with the LM35 sensor, there’s a 3 °C overshoot, a 5-minute rise time, and a 30-minute settling time. The DS18B20 sensor under PI control exhibits a 2.7 °C overshoot, a 5-minute rise time, and a 29-minute settling time. PD control demonstrates lower overshoot and faster response but longer rise times than PI control. Future research explores fuzzy control systems and proportional integral derivative (PID)-fuzzy hybrid control.
Effectiveness of Bluetooth communication of digital stethoscope using quality of service method Endang Dian Setyoningsih; Sumber Sumber; Triwiyanto Triwiyanto; Farid Amrinsani
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 22, No 4: August 2024
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v22i4.25882

Abstract

This study aims to design and evaluate a wireless electronic stethoscope that can transmit heart sound using Bluetooth HC-05 and Bluetooth 5.0 transmitter. This novel design contributes to the remote diagnosis and monitoring of heart conditions, especially for patients with infectious diseases. The heart sound signals are captured using a mic condenser mic, amplified, filtered, and converted to digital data by a microcontroller. The data are then transmitted by Bluetooth HC-05 to a module and by Bluetooth 5.0 transmitter to a headset. The quality-of-service parameters such as throughput, delay, and packet loss ratio (PLR) of the data transmission at different distances are measured. The results show that the wireless electronic stethoscope can transmit heart sound data with a small PLR of 0.10% and a throughput of 1002.5 bps. The study concludes that the wireless electronic stethoscope is an effective and useful device for examining heart conditions remotely, without compromising the functionality of the device
Evaluating the effectiveness of digital filtering techniques in electronic stethoscopes: a study of Kalman and Butterworth filters Endang Dian Setioningsih; Sumber Sumber; Triwiyanto Triwiyanto; Vugar Abdullayev; Farid Amrinsani; Bima Maulana Raharjo; Tetrik Fa’altin
Bulletin of Electrical Engineering and Informatics Vol 15, No 2: April 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i2.8674

Abstract

Heart sound, or phonocardiogram (PCG), signals are often distorted by noise from respiration, movement, and the surrounding environment, which complicates accurate cardiac feature extraction in portable monitoring systems. This study aims to design and evaluate an effective digital filtering method to enhance PCG signal quality obtained from a low-cost acquisition system based on a condenser microphone sensor and an ESP32 microcontroller. The main contribution of this work is the implementation and comparison of two noise-reduction approaches: Butterworth band-pass filters of various orders and the Kalman filter applied to PCG signals acquired from mannequin-based simulations. Data were recorded for 10 seconds at a 1000 Hz sampling rate, processed in MATLAB, and analyzed using the fast Fourier transform (FFT) to determine the optimal frequency ranges. Experimental results demonstrate that the 8th-order Butterworth band-pass filter achieved the highest signal-to-noise ratio (SNR) improvement, averaging 25.659 dB, outperforming other configurations. These findings indicate that an appropriately tuned Butterworth filter provides a simpler yet robust solution for real-time PCG denoising in embedded systems. Future work will integrate the filtering process directly into the ESP32 firmware and evaluate its performance on human subjects to enhance clinical applicability.