Perhitungan Efisiensi Perpindahan Panas pada Unit Cooler Di PT. XY Ratna Kristina Tarigan
JURNAL VOKASI TEKNIK Vol 1 No 03 (2023): November Issue 2023 | JUVOTEK JURNAL
Publisher : CV MEDAN TEKNO SOLUSI

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

PT. XY Medan is a company engaged in the production of NPK fertilizer. One of its products is NPK fertilizer with the formulation 12:12:17:2, which contains 12% nitrogen (N) from urea, 12% phosphorus (P2O5), 17% potassium (KCl), and 2% magnesium (MgO). One of the main stages in the production process is cooling, which is carried out using a rotary cooler operating at a rotational speed of 7 rpm and an inclination angle of 2°. The cooling medium is ambient air drawn into the rotary cooler by an exhaust fan. Heat transfer efficiency is an important parameter because insufficient or excessive cooling may affect the quality of the NPK fertilizer. In addition, evaluating heat transfer efficiency is necessary to determine whether the cooling equipment operates efficiently or requires process optimization. The average residence time of the fertilizer in the rotary cooler is 10 minutes. The average inlet temperature of the NPK fertilizer is 66.8 °C with a mass flow rate of 6,000 kg/h, while the average inlet air temperature is 34 °C with an average air flow rate of 12,626.6132 kg/h. The calculation results show that the average heat released by the NPK fertilizer during the cooling process is 28,478.9244 kcal/h, whereas the average heat absorbed by the cooling air is 26,332.98 kcal/h. Consequently, the average heat transfer efficiency of the rotary cooler is 82.09%. The maximum allowable moisture content of NPK fertilizer with the 12:12:17:2 formulation is 2%, while the average final moisture content obtained at the end of the process is 1.444%, indicating that the product meets the required quality standard.
Perhitungan Debit Koagulan Poly Aluminium Chloride (PAC) Yang Diinjeksikan Pada Air Baku Proses Pengolahan Air PT. X Ratna Kristina Tarigan
JURNAL VOKASI TEKNIK Vol 2 No 1 (2024): April Issue | JUVOTEK JURNAL
Publisher : CV MEDAN TEKNO SOLUSI

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Poly Aluminum Chloride is a chemical used to reduce water turbidity. Poly Aluminum Chloride will agglomerate dirt in water into larger particles so that it settles more easily. The amount of coagulant added to the water must be precise so that the turbidity of the water can be suppressed to the maximum. To find out the optimal dose, a jar test procedure was carried out. The jar test was carried out by adding coagulants with different variations. The jar test will give results on how variations in the amount of coagulant affect the turbidity level of the water. In water with a turbidity of 25.2 NTU, the optimum dose of PAC coagulant used was 30 ppm. With this dose, the PAC coagulant discharge injected into raw water at a water treatment plant is 56,0747 ml/s.