Life-Cycle Cost Analysis of a 220Ah Tubular Battery in a Solar-Powered Academic Setting Obiora Jeremiah Obiafudo; Godspower Onyekachukwu Ekwueme; Ugochukwu Richards Orji; Clement Nworji Obiora
Journal Majelis Paspama Vol. 3 No. 02 (2025): Journal Majelis Paspama, 2025
Publisher : Journal Majelis Paspama

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Reliable energy storage remains a critical challenge in sustaining solar-powered systems within academic environments, particularly in Nigeria where erratic grid supply hinders teaching and research activities. Batteries constitute the most cost-intensive component of solar installations, and their economic performance determines long-term viability. The study integrated MATLAB/Simulink simulations, field observations, and expert input. The analysis followed three stages: system modeling, performance evaluation, and economic benchmarking. Monocrystalline PV modules (220–330 W, 18–20% efficiency) were configured with 7° tilt and passive cooling to optimize performance in Nigeria’s tropical climate. A 60A MPPT controller and 1 kW inverter enhanced efficiency, while protections improved system reliability. Life-cycle cost analysis (LCCA) over 15 years at 10% discount rate compared tubular lead-acid and LiFePO₄ batteries, revealing LiFePO₄’s long-term cost advantage. Sensitivity analysis and benchmarking confirmed its superior cycle life, reduced maintenance, and lower levelized storage costs. The life-cycle cost analysis showed that tubular lead-acid batteries were cheaper upfront (₦92,000/kWh vs. ₦230,000/kWh) but incurred higher O\&M (₦46,000/kWh every 5 years) and required replacements at years 5 and 10, raising their 15-year cost to ₦400,200/kWh. LiFePO₄, though costlier (₦481,100/kWh total), offered longer lifespan, lower O\&M (₦18,400/kWh), and higher salvage value (₦34,500). Net Present Cost was lower for tubular (₦248,500/kWh vs. ₦289,200/kWh), yet LiFePO₄ delivered a better Levelized Cost of Storage (₦98/kWh vs. ₦127/kWh) and achieved payback in 8.2 years. Thus, tubular favored affordability, while LiFePO₄ provided superior long-term value and reliability for Nigerian universities. The study recommends a shift toward durable storage technologies to enhance reliability, reduce operating costs, and strengthen energy security in Nigerian universities.
Assessment of Digital Battery Management and Maintenance Protocols for Maximizing 220Ah Tubular Battery Lifespan Obiora Jeremiah Obiafudo; Godspower Onyekachukwu Ekwueme; Ugochukwu Richards Orji; Chibuzo Benjamin Nwanonobi
Siber International Journal of Digital Business (SIJDB) Vol. 3 No. 1 (2025): (SIJDB) Siber International Journal of Digital Business (July - September 2025)
Publisher : Siber Nusantara Review & Yayasan Sinergi Inovasi Bersama (SIBER)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38035/sijdb.v3i1.282

Abstract

Reliable energy storage is critical for sustainable power systems, particularly in academic environments where interruptions can disrupt teaching and research. Tubular lead-acid batteries, widely adopted for their affordability and robustness, often face reduced lifespan due to inadequate maintenance and poor monitoring practices. With the advent of digital technologies, battery management can now integrate real-time monitoring, predictive diagnostics, and automated alerts to improve efficiency and reliability. A three-phase framework—data collection and modeling, performance evaluation, and economic benchmarking—ensured coherence and reproducibility. Monocrystalline PV modules (220–330W, 18–20% efficiency) were mounted at a 7° tilt for optimal irradiance in Southern Nigeria, supported by passive cooling. A 60A MPPT charge controller and a 1kW pure sine wave inverter were modeled with high efficiency and protective features. Battery protocols were developed for both tubular lead-acid and LiFePO? types, balancing monitoring, maintenance, and cost quantification to maximize reliability, performance, and lifespan in academic settings. The results show clear differences between tubular lead-acid and LiFePO? batteries in maintenance, cost, and performance. Tubular systems demand weekly checks, monthly charging, and quarterly testing, totaling about 156 labor hours per year, compared to just 24 hours per year for LiFePO? with automated BMS monitoring. Results further indicate that incorporating digital monitoring reduces downtime, enhances predictive maintenance, and extends battery life. The study demonstrates that digital integration provides a cost-effective and sustainable framework for academic institutions, particularly in resource-constrained contexts.