MODIFIKASI Centrifuge DILENGKAPI SISTEM PENDETEKSI KETIDAKSEIMBANGAN SENTRIFUGASI BERBASIS ARDUINO Kusnadi Kusnadi; Galih Persadha; Hikmah Mayasari; Hendra Rasyid
Jurnal Kajian Ilmiah Kesehatan dan Teknologi Vol. 7 No. 1 (2025)
Publisher : Politeknik Unggulan Kalimantan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.52674/jkikt.v7i1.207

Abstract

In the laboratory, a device is needed that is able to separate suspended particles in liquids according to their particle size and density. Centrifuge is the separation of blood and other body fluids such as urine, in certain cases it is necessary to separate its constituent components to facilitate the examination process. Centrifugation balance is a critical aspect of its operation. Mass imbalances in the rotor can cause vibration, excessive noise, and even damage to the tool. Therefore, the development of a centrifugation imbalance detection system is an important step to identify and address imbalances. Rotation imbalances can result in sample holder rupture, centrifuge damage, and sample contamination. The factors that affect the rotational balance and vibration of the centrifuge are the balance of the sample position and the number of samples. The method used in the research is Research and Development. Test results from field data for power supply voltage of 12.21 Vdc with an error accuracy of 1.75 %. In the DC to DC Buck Converter test, the average voltage is measured at 5.005 Vdc, the error accuracy is 0.1 %. In the Arduino Uno pin test, the average voltage measured is 5.005 Vdc, the accuracy error is 0.1 %. In the centrifuge time test, a comparison of 15.02 minutes was obtained, with an error accuracy of 02 seconds, and an error accuracy of 0.2 %. The feasibility test of the tool differs samples from 1 ml to 4 ml and speeds from 1000 RPM to 4000 RPM, the feasibility test includes validation assessments, function tests, and material validators are obtained 100 % and 88 %, meaning that this tool is very feasible to use.
RANCANG BANGUN TIMBANGAN BERAT DAN TINGGI BADAN IDEAL BERDASARKAN METODE BROCHA DENGAN KELUARAN SUARA BERBASIS ARDUINO MEGA 2560 Kusnadi Kusnadi; Hikmah Maya Sari; Rakhmad Rizkiansyah; Elysa Aziza Putri
Jurnal Kajian Ilmiah Kesehatan dan Teknologi Vol. 6 No. 2 (2024)
Publisher : Politeknik Unggulan Kalimantan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.52674/jkikt.v6i2.159

Abstract

The measurement of a patient's weight and height is of great importance in the context of medical examinations, as it allows for the early detection of diseases. However, it is important to note that many individuals do not have an ideal body weight, with some being overweight and others underweight. Being overweight can lead to obesity, while being underweight is often associated with malnutrition. Therefore, the objective of this research is to develop a weight and height scale based on the Broch method with accurate output and printable results. The research methodology employed is research and development (R&D). The methodology employed in this research comprises preliminary research, product design, design review, design revision, product testing, and validation. Based on the results of the product testing, the following conclusions can be drawn: the adapter output voltage measurement is 12.13 VDC, with an error of 0.13 VDC and an error of 1.1%. The average voltage measured during testing of the Arduino Mega 2560 was 5.01 VDC, with an error of 0.01 VDC and an error of 0.2%. Ultrasonic sensor readings at a distance of 185 cm demonstrated no error (0 cm), with an error of 0%. Load cell readings at a distance of 40 kg exhibited an error of 0.67 kg and an error of 1.6%. The validation assessment received a rating of 100% from material experts and 96% from media experts. Referring to the feasibility category table, the result is designated as "very eligible".