APPLICATION EFFECT OF HAND MIXER AND OVERHEAD MIXER ON MIXING PERFORMANCE FOR THE MANUFACTURE OF ARTIFICIAL LEATHER Dewi Nurhidayati
Berkala Penelitian Teknologi Kulit, Sepatu, dan Produk Kulit Vol. 22 No. 1 (2023): Berkala Penelitian Kulit, Sepatu dan Produk Kulit
Publisher : Politek ATK Yogyakarta Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58533/3jerca37

Abstract

The mixing process is necessary for the manufacture of a product, one of which is the manufacturing process of artificial leather. The mixing process in the manufacture of artificial leather aims to mix raw materials and additives such as fillers, stabilizers, plasticizers, and others. The mixing process is carried out using a mixer. This study aims to determine the effect of using mixers that have different specifications. The mixer used is the Hand Mixer Miyako SM-625 with the Overhead Mixer IK RW 20. Both of these mixers have differences in speed and type of agitator.From the results of organoleptic test, both of these mixers there was no difference. But the results of the physical test showed that the values of tensile strength, elongation, and tear strength were higher when using the IK RW 20 Overhead Mixer. This indicated that both mixers could be used in the manufacture of artificial leather, but to obtain measurable test results, using the IK RW 20 Overhead Mixer was recommended, seen from the difference in each of the physical test parameters.
LABORATORY SCALE OF RAYON FIBER MANUFACTURING: MANUAL STIRRING AND STIRRING USING A MAGNETIC STIRRER Dewi Nurhidayati; Warmiati; Wijayanti
Berkala Penelitian Teknologi Kulit, Sepatu, dan Produk Kulit Vol. 23 No. 1 (2024): Berkala Penelitian Kulit, Sepatu, dan Produk Kulit
Publisher : Politek ATK Yogyakarta Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58533/kjmm1s79

Abstract

Laboratory scale production of rayon fiber has been carried out using manual stirring and a magnetic stirrer. The aim of this research is to compare rayon fiers produced through manual stirring and magnetic stirrer stirring. Experiments on making rayon on a laboratory scale are carried out for educational purposes which often have obstacles due to the limited availability of mixing equipment, such as magnetic stirrer. The method used in making rayon in this research is through the formation of cuprammonium ions. The results show that there is no significant difference between rayon produced manual stirring and magnetic stirrer stirring. It means that the manual mixing can be applied in the learning process for making rayon due in order to get around the limitations of available mixing equipments.
MOISTURE CONTENT MEASUREMENT IN GELATIN: A COMPARISON OF GRAVIMETRIC METHODS USING MOISTURE ANALYZER AND OVEN Warmiati; Dewi Nurhidayati
Berkala Penelitian Teknologi Kulit, Sepatu, dan Produk Kulit Vol. 23 No. 1 (2024): Berkala Penelitian Kulit, Sepatu, dan Produk Kulit
Publisher : Politek ATK Yogyakarta Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58533/061s5z77

Abstract

The measurement of water content in gelatin samples in the practical activities in the Instrumentation and Polymer Engineering Laboratory is conducted using the gravimetric method with the Moisture Analyzer Sartorius Type MA 45. Meanwhile, the method acknowledged and approved by AOAC International is the Oven method. This research aims to compare the measurement results of the Moisture Analyzer with the reference method, namely the Oven method referring to AOAC, to determine if there is a statistically significant difference in the results. The results of both methods are compared using a paired T-test, yielding a calculated T-value (Tstat) of 0.7519 and a tabulated T-value of 2.2622. These results indicate that Tstat ≤ the tabulated T-value at a 95% confidence level, thus accepting the null hypothesis (H0). This suggests that μa=μb, meaning that there is no significant difference between the two methods. The precision test results for both methods also meet the criteria, with %RSD ≤ 2% and %RSD ≤ 2/3 CV Horwitz.
ANALYSIS OF METAL CONTENTS IN WELL WATERAT THE ATK YOGYAKARTA POLYTECHNIC LABORATORY Warmiati; Wijayanti; Armila Zahra Tawarniate; Dewi Nurhidayati
Berkala Penelitian Teknologi Kulit, Sepatu, dan Produk Kulit Vol. 23 No. 1 (2024): Berkala Penelitian Kulit, Sepatu, dan Produk Kulit
Publisher : Politek ATK Yogyakarta Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58533/5wrznv09

Abstract

This sudy has been conducted to determine the metal content in water used for laboratory activities at Politeknik` ATK Yogyakarta. The water used for laboratory processes should ideally be free from metal content to avoid contamination and corrosion. The metal content analyzed in this research includes Cu, Pb, Cr, adn Fe. The analysis method used is spectrophotometry, specifically Atomic Absoprtion Spectrophotometry (AAS), using standard series. The samples to be analyzed are first destructed according to the method outlined in SNI 6989 – 84: 2019. The analysis results obtained are as follows: Cu content in water sample is 0.046 mg/L, Pb content is 3.031 mg/L, Cr metal is 0.023 mg/L, and Fe content is 6.372 mg/L.