Application of Waste Heat Recovery Systems for Evaluating the Effectiveness and Electrical Energy Consumption Seaweed Convective Dryer Nicolas - Titahelu; Raja Bonan Dolok Sormin; Wulfilla Maximilian Rumaherang; Jandri Louhenapessy; Cendy Sophia Edwina Tupamahu; Nataliano Resky Inuhan
TEKNIK Vol 47, No 1 (2026)
Publisher : Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/teknik.v47i1.62446

Abstract

The research has practical implications for the design and operation of seaweed convective dryers, particularly in the context of energy conservation. Implementing a Waste Heat Recovery System (WHRS) to utilize waste heat from convective dryers that have been wasted into the environment is a promising development. This research aims to obtain the effective air velocity at which the effectiveness of the seaweed convective dryer is at its maximum and obtain drying time and minimum electrical energy consumption for operating conditions with and without the application of WHRS. The experimental method was carried out by varying the air velocity value from 1 to 5 m/s at certain temperatures, heat input, and humidity. Capturing and recording measured data after reaching steady conditions. The experimental results show that effectiveness decreases as air velocity increases, where the maximum effectiveness at minimum air velocity is 46.83% and 46.61% for operating conditions with and without WHRS implementation, where the average deviation value is 1.38%. On the other hand, drying time and minimum electrical energy consumption are at a maximum air velocity of 20.97 hr and 21.25 hr, respectively, and 19 kWh and 19.45 kWh for operating conditions with and without WHRS application, where the deviation of the average value in electrical energy consumption is 1.98%. It was concluded that the maximum air velocity can be used for convective drying of seaweed by applying WHRS, presenting a new and exciting approach to seaweed drying with significant potential benefits for energy conservation.
Thermal Performance Improvement of a Counter-Flow Double-Pipe Heat Exchanger Using a Twisted Turbulator Eric Maspaitella; Nicolas Titahelu; Cendy Sophia Edwina Tupamahu
Journal of Engineering Science and Technology Management (JES-TM) Vol. 6 No. 1 (2026): March-May 2026
Publisher : Journal of Engineering Science and Technology Management

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jestm.v6i1.387

Abstract

Internal combustion systems, such as 5 KVA generators, convert only part of fossil fuel energy into useful work, while the remaining energy is released as waste heat through exhaust gas, cooling systems, and mechanical losses. This study aims to improve the thermal performance of a double-pipe heat exchanger using a twisted turbulator by varying the pitch-to-diameter ratio, p/d, from 0.8 to 3.9. The experiment was conducted at the Thermodynamics and Heat Transfer Laboratory, Faculty of Engineering, Pattimura University, using five p/d variations, namely 0.8, 1.6, 2.4, 3.2, and 3.9. The operating conditions were maintained constant, with a hot fluid inlet temperature of 523.2 K, a cold fluid inlet temperature of 308.2 K, a cold fluid velocity of 1.0 m/s, and a hot fluid velocity of 5.0 m/s. The main components included a copper tube bank, steel pipe casing, thermocouples, flowmeter, pipe system, and valves. The performance parameters were evaluated using Reynolds number, Prandtl number, friction factor, Nusselt number, overall heat transfer coefficient, actual heat transfer rate, maximum heat transfer rate, and effectiveness. The results show that the best performance was obtained at p/d = 0.8, producing a cold fluid outlet temperature of 425.84 K, Nusselt number of 7.569, overall heat transfer coefficient of 0.2029 W/m²·K, and effectiveness of 39.95%. The lower p/d ratio enhanced swirl flow, turbulence intensity, fluid mixing, and thermal boundary layer disruption. Therefore, p/d = 0.8 is recommended for improving the tested heat exchanger performance in small-scale waste heat recovery applications under laboratory operating conditions and design.