Claim Missing Document
Check
Articles

Found 2 Documents
Search

Pengaruh Penggunaan Variasi Bahan Bakar dan Beban Kelistrikan Terhadap Kinerja Engine Diesel Safri Gunawan; Mulia Mulia; Rahma Doni; Yanuardi Gulo; Muhammad Reza Pratama; Yodi Sitohang; Sofiya Vari Zan'nah; Dery Affandi
IRA Jurnal Teknik Mesin dan Aplikasinya (IRAJTMA) Vol 4 No 1 (2025): April
Publisher : CV. IRA PUBLISHING

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56862/irajtma.v4i1.196

Abstract

The global energy crisis has driven efforts to find alternative fuels that are efficient and environmentally friendly. One focus is testing the performance of diesel engines against variations in fuel. This study aims to analyse the effect of diesel fuel types, including Bio Solar, Dexlite, and Pertamina Dex, with cetane numbers of 48, 51, and 53, respectively, on diesel engine performance in terms of power, torque and specific fuel consumption parameters at various levels of electrical load. The method used is an experiment involving a graded electrical load test ranging from 300 to 1500 Watts. Data were collected under stationary conditions at 1500 rpm using instruments such as voltmeters, ammeters, tachometers, and fuel burettes. The results show that Pertamina Dex produces the highest power at peak load due to its high cetane number, while Bio Solar provides the highest torque due to a longer combustion delay. The highest specific fuel consumption occurs in Pertamina Dex at low loads, while Bio Solar is more efficient at low load conditions.
Analisa Beban dan Ketinggian Penumpukan Terhadap Tekanan Hidrolik Reach Stacker Abdur Razaq; Supriadi Supriadi; Mulia Mulia
JURNAL VOKASI TEKNIK Vol 4 No 01 (2026): April ISSUE | JUVOTEK JURNAL
Publisher : MEDAN TEKNO SOLUSI

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study aims to analyze the hydraulic system performance of a reach stacker at PT. XYZ by calculating the pump power and the pressure required for the boom spreader actuator. The research methodology involved direct field observations to obtain measured operational data. The results indicate that the hydraulic power generated by the pump to circulate oil is 1.33811 kW (1.79443 HP). The required hydraulic pressure varies based on load and stacking height, with the highest values being 1.88 Bar (20 ft container) and 2.00 Bar (40 ft High Cube) at the first stacking level. As the stacking height increases to level four, the required pressure decreases to its lowest points at 0.031 Bar and 0.044 Bar, respectively. This research contributes to mapping hydraulic energy requirements in container terminal heavy equipment operations.