Structural Integrity Assessment of A Low Temperature Separation Unit (LTSU) Strainer Handle-Plate in Oil and Gas Operations: Coupled CFD and FEA Analysis of Fluid-Induced Loads Mohd Azni Md Kasim; Mohd Azahari Razali; Norfakhira Mohd Nor; Iman Fitri Ismail; Masataro Suzuki; Amnur Akhyan
Scientific Contributions Oil and Gas Vol 49 No 2 (2026)
Publisher : Testing Center for Oil and Gas LEMIGAS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29017/scog.v49i2.2033

Abstract

Structural strainers play a vital role in oil and gas processing facilities by removing solid contaminants from process fluids and protecting downstream equipment. In a Low Temperature Separation Unit (LTSU), a premature failure occurred at the handle punching plate connection of a strainer after approximately five years of continuous operation. This study aims to identify the root cause of the failure and to evaluate improved design configurations capable of withstanding operational loads. A coupled Computational Fluid Dynamics (CFD) and Finite Element Analysis (FEA) methodology was employed. CFD simulations were conducted to determine internal flow characteristics, pressure distribution, and pressure drop under both normal and contingency operating conditions. The resulting fluid-induced pressure loads were transferred to structural models for FEA to evaluate von Mises stress, displacement, strain, and unity check (UC) values for three designs with different punching plate thicknesses. The original design (Geometry A) exhibited high stress concentration at the handle–plate interface and UC values exceeding allowable limits, explaining the observed field failure. Geometry B showed improved performance under normal conditions but approached critical limits during contingency operation. Geometry C demonstrated the best structural integrity, maintaining UC values within acceptable limits in all cases while reducing peak stresses and deformation. The results confirm that insufficient plate thickness was the primary cause of failure and that increasing thickness significantly enhances structural reliability. The study demonstrates that the coupled CFD–FEA approach is an effective tool for failure diagnosis and design optimisation of process equipment subjected to fluid-induced loading in oil and gas operations.
Effect of Cone Design on the Structural Integrity Assessment of an Oil & Gas Conical Perforated Strainer Using CFD-Coupled Finite Element Analysis Mohd Azni Md Kasim; Mohd Azahari Razali; Nur Syafiqah Adha Narrudin; Norfakhira Mohd Nor; Iman Fitri Ismail; Masataro Suzuki; Amnur Akhyan
Scientific Contributions Oil and Gas Vol 49 No 3 (2026)
Publisher : Testing Center for Oil and Gas LEMIGAS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29017/scog.v49i3.2130

Abstract

Cone strainers play an important role in oil and gas process piping systems and are often subjected to high-pressure fluid flow. The early failure of a cone strainer in a Low Temperature Separation Unit (LTSU) during prolonged service motivated a detailed structural integrity investigation. A combined Computational Fluid Dynamics (CFD) and Finite Element Analysis (FEA) method was used to assess the structural behaviour of a conical perforated strainer under actual operating conditions (30.51 bar (a), 94.3 °C) and contingency conditions (36.61 bar (a), 113.16 °C), the latter representing the pressure and temperature excursions encountered intermittently during normal service. Pressure, temperature and wall shear stress obtained from steady-state CFD were applied to the structural model through one-way fluid–structure interaction, and structural adequacy was expressed as a Unity Check (UC), the ratio of the peak von Mises stress to an allowable stress of 336 MPa. The baseline 2 mm punching plate (Geometry A) was adequate under actual conditions (UC = 0.87) but failed under contingency conditions, reaching 371.8 MPa and UC = 1.11, as a result of flow-induced bending across the large, low-stiffness perforated cone surface. Thickening the punching plate to 4 mm (Geometry B) reduced the contingency peak stress by 13.4% to 322.0 MPa and the UC to 0.96, but transferred load into the ring plate, whose UC rose from 0.95 to 0.99 and which thereby became the new critical component. Repositioning the ring plate (Geometry C) reduced the punching plate UC to 0.91 and the ring plate UC to 0.30, at the cost of a 19.7% increase in pressure drop, from 7273 Pa to 10894 Pa. Geometry C is therefore proposed as the optimal configuration, and the CFD-informed FEA workflow provides a reliable framework for integrity evaluation and design optimisation of conical strainers used in the oil and gas industry.