Indonesia is located at the convergence of three major tectonic plates, making it one of the countries with the highest levels of seismic activity in the world. Therefore, every building must be designed and evaluated to ensure adequate resistance to earthquake loads. This study aims to analyze the structural strength and evaluate the seismic performance of the four-story commercial building at the Citraland Medan Sampali Project using the nonlinear static (pushover) analysis method. The study was conducted by developing a three-dimensional structural model using SAP2000 software in accordance with the provisions of SNI 1726:2019. The structural performance was evaluated based on the ATC-40 Capacity Spectrum Method through the analysis of the capacity curve, the formation of plastic hinges, and the determination of the structural performance level. The analysis results indicate that the structure exhibits nonlinear behavior as the earthquake load increases. The maximum story drift values obtained were 0.0011494 in the X-direction and 0.0009923 in the Y-direction, both of which are within the allowable limits specified by ATC-40. Plastic hinges developed gradually in the beams and columns without indicating sudden structural failure. Based on the evaluation, the structural performance level is classified as Immediate Occupancy (IO), indicating that the building remains safe for occupancy after the design earthquake with only minor structural damage. Therefore, the four-story commercial building at the Citraland Medan Sampali Project has sufficient capacity to withstand the design earthquake and satisfies the structural performance requirements based on the ATC-40 method.