Claim Missing Document
Check
Articles

Found 2 Documents
Search

The influence of staircase geometry and spatial configuration on the enhancement of natural ventilation in urban residential buildings Khotijah Lahji; Agus Budi Purnomo; Inavonna
ARTEKS : Jurnal Teknik Arsitektur Vol 11 No 1 (2026): ARTEKS : Jurnal Teknik Arsitektur | January 2026 ~ March 2026
Publisher : Program Studi Arsitektur Fakultas Teknik Universitas Katolik Widya Mandira

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30822/arteks.v11i1.4905

Abstract

In densely populated tropical urban contexts, row houses (RD) have increasingly emerged as a prevalent residential solution owing to their efficiency in land utilization and economic affordability. Nevertheless, the compact and contiguous spatial configuration characteristic of this housing typology significantly restricts the availability of natural ventilation openings, impedes effective cross ventilation, and consequently reduces levels of thermal comfort and indoor air quality. Under such conditions, occupants tend to rely more heavily on mechanical ventilation systems, which in turn leads to increased energy consumption and a decline in overall environmental sustainability. This study explores the potential role of staircases as vertical void elements capable of enhancing natural ventilation performance through the application of the stack effect mechanism. An experimental investigation was carried out to analyze the influence of sixteen combinations derived from variations in staircase geometry (I, L, U, ?, and their mirrored configurations), tread construction (solid and perforated), and staircase placement (front, center, and rear) on natural ventilation performance within row house typologies. A quantitative research approach was adopted through the application of Computational Fluid Dynamics (CFD) simulations to evaluate airflow behavior and thermal conditions. The findings indicate that staircases with a massive U-shaped construction geometry demonstrate the most optimal natural ventilation performance, achieving an air velocity of 5 m/s and a temperature of 33.5°C. Specifically, within the U-shaped staircase configuration, airflow velocity increased from stagnant conditions to an active state, reaching 4.62 m/s, accompanied by a temperature reduction of approximately 1°C. These results emphasize the significance of staircases as effective passive design components and underscore their potential contribution to improving energy efficiency and promoting sustainability in tropical urban residential architecture.
Preliminary design geometry for predicting natural ventilation performance in row houses Khotijah Lahji; Agus Budi Purnomo; Inavonna
ARTEKS : Jurnal Teknik Arsitektur Vol 11 No 3 (2026): ARTEKS : Jurnal Teknik Arsitektur | July 2026 ~ September 2026
Publisher : Program Studi Arsitektur Fakultas Teknik Universitas Katolik Widya Mandira

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30822/arteks.v11i3.5726

Abstract

The Computational Fluid Dynamics (CFD) prediction tool has demonstrated a high degree of accuracy in modeling airflow velocity; however, its application requires comprehensive design data, making it more appropriate for use during advanced stages of the architectural design process. At the conceptual design stage, tools capable of predicting airflow velocity remain relatively limited. Therefore, this study aims to develop a geometry-based prediction tool that is simple, accessible, rapid, practical, and sufficiently accurate for early-stage architectural design. A quantitative research approach was employed, beginning with CFD simulations based on geometric or independent-variable indicators across 212 cases of two-story row house designs to obtain accurate airflow-velocity values as the dependent variable. The processed initial-design geometry data and CFD simulation results were subsequently analyzed using linear regression through the enter and stepwise methods in SPSS. The initial prediction equation was selected based on the model with the highest R² value and the smallest number of determining variables. The findings yielded an R² value of 0.738, determined by four geometric or independent variables: (1) building width (-), (2) number of doors on the second floor, (3) width of the window inlet on the front facade of the second floor, and (4) area of the vertical stair void. This prediction tool is effective for application during the conceptual design stage. A further model produced an R² value of 0.867 based on 16 geometric or independent variables; although this model provides a higher level of predictive accuracy, its greater complexity makes it more suitable for application during the advanced design stage. This study addresses the existing gap in early-stage prediction tools by introducing a novel building-geometry-based predictive approach in the form of a linear equation that is practical, rapid, straightforward, and sufficiently accurate for supporting natural ventilation assessment during the early design stage without compromising architectural design creativity.