PT XYZ is a manufacturing company that produces automotive batteries. One of the critical stages in battery production is the charging line, which plays an important role in determining the final quality of the product. Based on production data from January to May 2024, 578 defective units were found out of a total production of 130,800 units, with the highest defects occurring in the NS60 type. This study aims to analyze quality control on the charging line using the Six Sigma approach with the DMAIC stages (Define, Measure, Analyze, Improve, Control), identify the dominant types of defects, calculate the DPMO value and sigma level, analyze the root causes of defects, and provide improvement recommendations. The research method used is descriptive quantitative with a case study approach. The results show that the dominant defect type is pole defect 54.3%, followed by burn defect 23.4% and white defect 22.3%. The DPMO value obtained is 1,473 with a sigma level of 4.474, indicating good quality performance but still leaving room for improvement. Fishbone diagram analysis reveals that the main root cause of pole defects is the worn/dented physical condition of the pendulum and jumper cables, causing the pole not to fit perfectly and resulting in overheating. Improvement recommendations are formulated using the 5W+1H method, including regular component replacement, SOP development, operator training, and continuous monitoring through control charts. With the implementation of these recommendations, it is expected that the defect rate will decrease and the quality of battery products will further improve.