This Author published in this journals
All Journal Jurnal Kajian Ruang
Claim Missing Document
Check
Articles

Found 1 Documents
Search

PERENCANAAN PERKUATAN STRUKTUR GEDUNG RSUD SURADADI AKIBAT PENAMBAHAN LANTAI DENGAN FIBER REINFORCED POLYMER Irkham Fauzi; antonius antonius; abdul rochim
Jurnal Kajian Ruang Vol 6, No 2 (2026): September
Publisher : Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30659/jkr.v6i2.52433

Abstract

ABSTRAKPenelitian ini menganalisis kinerja struktur Gedung ICU–PICU–NICU RSUD Suradadi akibat penambahan lantai dari tiga menjadi lima lantai serta menentukan kebutuhan perkuatan menggunakan Carbon Fiber Reinforced Polymer (CFRP). Pemodelan dilakukan dengan ETABS v20.10 mengacu pada SNI 2847:2019, SNI 1727:2020, dan SNI 1726:2019. Hasil analisis menunjukkan peningkatan gaya aksial kolom sebesar 48%–52% akibat penambahan lantai, yang menyebabkan rasio kapasitas (demand-to-capacity ratio) kolom K1, K2, dan K3 melampaui 1,0 sehingga struktur eksisting tidak lagi memenuhi persyaratan kekuatan. Penerapan CFRP melalui mekanisme confinement terbukti meningkatkan kapasitas aksial kolom sebesar 23,5%–30,6% tergantung jumlah lapisan, sehingga rasio kapasitas turun menjadi kurang dari 1,0 dan elemen kembali ke kondisi aman. Evaluasi konfigurasi menunjukkan bahwa jumlah lapisan CFRP yang dibutuhkan berbeda antar tipe kolom, bergantung pada tingkat rasio kapasitas awal. Dengan demikian, perkuatan CFRP dinilai mampu mengatasi kegagalan elemen akibat penambahan lantai dan layak diterapkan untuk memastikan keamanan struktur, dengan catatan bahwa penelitian ini terbatas pada elemen kolom dan tidak menganalisis fondasi serta elemen struktur lainnya secara rinci.Kata Kunci: CFRP, penambahan lantai, ETABS, perkuatan, kolom ABSTRACTThis study analyzes the structural performance of the Suradadi Regional General Hospital (RSUD) ICU–PICU–NICU building following an expansion from three to five stories and determines the strengthening requirements using Carbon Fiber Reinforced Polymer (CFRP). Modeling was conducted using ETABS v20.10 in accordance with SNI 2847:2019, SNI 1727:2020, and SNI 1726:2019. Analysis results indicate a 48%–52% increase in column axial loads due to the additional stories; this caused the demand-to-capacity ratios of columns K1, K2, and K3 to exceed 1.0, meaning the existing structure no longer met strength requirements. The application of CFRP via a confinement mechanism was shown to increase column axial capacity by 23.5%–30.6%, depending on the number of layers; consequently, the demand-to-capacity ratio dropped below 1.0, restoring the elements to a safe condition. Configuration evaluations revealed that the required number of CFRP layers varied by column type, depending on the initial demand-to-capacity ratio. Thus, CFRP strengthening is considered capable of addressing element failure resulting from the additional stories and is a viable solution for ensuring structural safety, noting that this study was limited to column elements and did not analyze the foundation or other structural elements in detail.Keywords: CFRP, additional stories, ETABS, strengthening, column