p-Index From 2021 - 2026
0.444
P-Index
This Author published in this journals
All Journal Jurnal Surya Energy
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Sistem Kontrol Pada Unit Proses Chilled Water System Muhardika; Wiwik Wiharti; Riza Widia; Andira Agustin; Yani Kamisa Putri; Yudia Meka Seftiani
Jurnal Surya Energy Vol. 10 No. 1 (2025)
Publisher : Teknik Elektro, Universitas Muhammadiyah Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32502/jse.v10i1.916

Abstract

Penelitian ini bertujuan untuk mengevaluasi bagaimana sistem kontrol otomatis pada unit Process Chilled Water (PCW) di PT. Infineon berfungsi dalam mendukung proses pendinginan yang efisien. Kami fokus pada kinerja sistem dalam mengatur suhu dan tekanan, serta bagaimana kontrol Proportional-Integral-Derivative (PID) berperan dalam menjaga kestabilan operasional. Hasil penelitian menunjukkan bahwa sistem ini bekerja dengan baik, mampu mempertahankan suhu dalam rentang 15˚C hingga 23°C dan tekanan antara 2,5 hingga 3,2 bar. Kontrol PID yang diterapkan terbukti responsif terhadap perubahan suhu dan tekanan, sehingga sistem dapat menyesuaikan diri dengan cepat dan akurat. Dengan menggunakan sensor tekanan dan suhu, sistem secara otomatis mengaktifkan atau menonaktifkan pompa, yang membantu menjaga kondisi operasional yang optimal. Salah satu aspek penting dari sistem ini adalah tampilan Human-Machine Interface (HMI), yang memudahkan operator dalam memantau status operasional secara real-time. HMI memungkinkan operator untuk membuat keputusan yang lebih cepat dan tepat, serta meningkatkan respons terhadap situasi darurat. Penelitian ini juga menunjukkan bahwa integrasi antara sistem kontrol otomatis dan HMI tidak hanya meningkatkan efisiensi, tetapi juga mengurangi kemungkinan kesalahan manusia dalam pengelolaan proses pendinginan.Secara keseluruhan, temuan dari penelitian ini menunjukkan bahwa penerapan sistem kontrol otomatis di PT. Infineon memberikan kontribusi signifikan terhadap peningkatan kinerja sistem pendinginan. Kami berharap hasil penelitian ini dapat menjadi referensi berharga bagi industri lain yang ingin menerapkan sistem kontrol otomatis serupa untuk meningkatkan efisiensi operasional mereka.
Studi Evaluasi Rewinding Motor Induksi Tiga Fasa 1,5 kW 3000 rpm dengan Parameter Tahanan Isolasi dan Arus Tanpa Beban Rayhan Shadiqi; Riza Widia; Wiwik Wiharti; Aldi Rahman; Akbar Abadi
Jurnal Surya Energy Vol. 11 No. 1 (2026)
Publisher : Teknik Elektro, Universitas Muhammadiyah Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32502/jse.v11i1.1700

Abstract

Three-phase induction motors are widely used as electric drives in industrial sectors; therefore, their reliability and operational condition must be continuously maintained. One common repair method applied to induction motors experiencing winding damage is the rewinding process. This study presents an evaluation of the rewinding results of a three-phase induction motor rated at 1.5 kW with a nominal speed of 3000 rpm, conducted at the Electrical and Instrumentation Workshop Unit of PT. Semen Padang. The objective of this research is to assess the operational feasibility of the motor after rewinding by examining the conformity of electrical parameters, the quality of the insulation system, and the phase current balance. The research methodology includes collecting nameplate data as a reference, documenting stator windings, performing a visual evaluation of the stator condition, and conducting electrical tests comprising winding resistance measurement, insulation resistance (Rsi) testing, Polarization Index (PI) evaluation, and no-load current measurement. The test results indicate that the winding resistance values are balanced at 4.6 Ω for each phase, while the insulation resistance ranges from 1.80 to 3.31 GΩ with a Polarization Index value of 2.17. The no-load current test results show an average current of 1.29 A, corresponding to approximately 41% of the rated current specified on the nameplate, with a current unbalance of 2.3%. Based on these results, it can be concluded that the rewinding process was successfully performed and the induction motor meets the technical requirements and is suitable for re-operation.