p-Index From 2021 - 2026
0.408
P-Index
This Author published in this journals
All Journal KOLONI
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Perbandingan Informasi Anatomi Shoulder Joint Proyeksi Supraspinatus Outlet Metode Neer Dengan Arah Sinar 10° Dan 15° Caudad Km. Agus Bima Sakti; Ni Kadek Mas Virayani; I Made Wahyu Candra
KOLONI Vol. 5 No. 3 (2026): SEPTEMBER 2026
Publisher : Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/koloni.v5i3.1206

Abstract

Shoulder impingement syndrome is one of the major causes of shoulder pain that requires radiographic examination to evaluate the subacromial space. The supraspinatus outlet projection using the Neer method is commonly used to demonstrate this space; however, variations in the central ray direction may affect the quality of the anatomical information obtained. This study aimed to determine the differences in anatomical information of the shoulder joint on the supraspinatus outlet projection using the Neer method with 10° and 15° caudad central ray directions. This study employed a quantitative experimental approach using a within-subject comparison design. The sample consisted of six volunteers, each of whom underwent two radiographic examinations using 10° and 15° caudad central ray directions, resulting in 12 radiographic images. The images were evaluated by three radiologists based on five anatomical components: the glenohumeral joint, acromioclavicular joint, supraspinatus outlet area, superimposition of the humeral head, and posterior process of the acromion. The data were analyzed descriptively by comparing the anatomical information scores obtained using the 10° and 15° caudad central ray directions. The results showed that all samples demonstrated an increase in anatomical information scores when using the 15° caudad central ray direction, with a mean total score of 131.56 compared with 120.28 for the 10° caudad direction. The greatest increase was observed in the posterior process of the acromion component, with a mean difference of 3.33 points. Based on these findings, the 15° caudad central ray direction provided more optimal anatomical visualization than the 10° caudad direction in the supraspinatus outlet projection using the Neer method and may therefore improve the quality of diagnostic information in the evaluation of shoulder impingement syndrome.
Analisis Perubahan Teknik Radioterapi Imrt Menjadi 3D-CRT Pada Kasus Retinoblastoma Pediatrik Di Instalasi Radioterapi RSUD Welas Asih Provinsi Jawa Barat Dony Rachmadhan; Km. Agus Bima Sakti; Nur Azis
KOLONI Vol. 5 No. 3 (2026): SEPTEMBER 2026
Publisher : Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/koloni.v5i3.1236

Abstract

Retinoblastoma is the most common intraocular malignancy in children and requires appropriate radiotherapy management to achieve optimal tumor control while minimizing radiation exposure to surrounding healthy tissues. Advanced radiotherapy techniques such as Intensity-Modulated Radiation Therapy (IMRT) offer superior dose conformity; however, technical limitations in clinical practice may necessitate alternative approaches such as Three-Dimensional Conformal Radiation Therapy (3D-CRT). This study aims to evaluate the dosimetric impact of transitioning from IMRT to 3D-CRT in a pediatric retinoblastoma case. A descriptive qualitative case study approach was conducted through direct observation, medical record documentation, and interviews with radiotherapy professionals. The patient received a total radiation dose of 45 Gy in 25 fractions, consisting of 20 fractions using IMRT and 5 fractions using 3D-CRT. Dosimetric evaluation was performed using Dose Volume Histogram (DVH) analysis to assess Planning Target Volume (PTV) coverage and dose constraints to Organs at Risk (OAR). The results showed that more than 95% of the PTV received the prescribed dose, while doses to OARs such as the eye, optic nerve, lens, brainstem, and brain remained within acceptable tolerance limits. These findings indicate that the transition from IMRT to 3D-CRT was able to maintain adequate target dose coverage and keep OAR doses within safe limits from a dosimetric perspective.