Claim Missing Document
Check
Articles

Found 3 Documents
Search

Efficiency Study Analysis of Electrical Energy in Container Stacking Equipment Rubber Tyred Gantry Crane (RTGC) Using Hybrid Energy Source Method Salam Maulana; Harry Ramza; Agus Sofwan
International Journal of Advanced Multidisciplinary Vol. 3 No. 1 (2024): International Journal of Advanced Multidisciplinary (April-June 2024)
Publisher : Greenation Publisher

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38035/ijam.v3i1.509

Abstract

This research to perform Efficiency Study Analysis Of electrical energy In Container Stacking Equipment Rubber Tyred Gantry Crane (RTGC) Using Hybrid Energy Source Method. RTGC gets power supply from Engine Diesel Generator with capacity of 350 kW. However, Genset power source in RTGC has drawbacks, such as when RTGC condition does not move (stationary) can lead to waste of fuel on diesel engine drivers. the Hybrid Energy Source is one of the technology which combines electrical energy source from generators and batteries, The battery of hybrid system can obtain electric energy saving until 32%, where for the Hoist system 11,72 %, Trolley system 33,63 % dan Gantry system 7,58 %.
Design of Control and Monitoring System for Electrical Power on kWh Meter Based on Internet of Things (IoT) Agus Sofwan; Abdullah Multi; Mohammad Azli; Nana Sujana
International Journal of Advanced Multidisciplinary Vol. 4 No. 3 (2025): International Journal of Advanced Multidisciplinary (October - December 2025)
Publisher : Greenation Publisher

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38035/ijam.v4i3.1365

Abstract

Electricity theft is the illegal use of electrical power without proper authorization and payment. This act causes losses to the electricity provider and the public, poses safety hazards, and violates the law. Perusahaan Umum Daerah (PERUMDA) Tuah Sekata of Pelalawan Regency, as a regional-owned enterprise responsible for electricity distribution to the community, annually detects indications of electricity theft through field inspections. To simplify the identification process and reduce operational costs, an Internet of Things (IoT)-based device was designed to monitor and control customers’ electricity consumption. The device utilizes a power supply as a 5V DC voltage source, a PZEM-004T sensor to measure voltage, current, power, and energy, an LCD 16x2 to display measurement results, and a 5V relay to connect or disconnect the customer’s power supply. An ESP32 microcontroller processes the data and transmits it via Wi-Fi to the Blynk application, which serves as an online monitoring interface. The device developed in this study not only facilitates real-time monitoring of electricity consumption but also serves to detect and prevent potential electricity theft. The experimental results show that, for voltage measurements, the average percentage error obtained was 0.41% (Device IoT 1), 0.29% (Device IoT 2), and 0.38% (Device IoT 3). Meanwhile, for current measurements, the average error rates were 8.42% (Device IoT 1), 8.66% (Device IoT 2), and 8.60% (Device IoT 3). Based on the experimental results, it can be concluded that the three developed IoT devices have an error rate of less than 10% (classified as very good), making them feasible for use in monitoring electrical power consumption.
Optimization of Stadium Building Operational Costs by Implementing Green Building Design Concepts Agus Sofwan; Abdullah Multi; Heri Sucipto
International Journal of Advanced Multidisciplinary Vol. 4 No. 3 (2025): International Journal of Advanced Multidisciplinary (October - December 2025)
Publisher : Greenation Publisher

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38035/ijam.v4i3.1429

Abstract

Currently, all buildings constructed by the government are required to implement the Green Building (BGH) principles. In addition to complying with existing regulations, the implementation of BGH also offers several benefits, including creating more environmentally friendly buildings and achieving more efficient operational costs. In this study, the method used involved collecting data from survey reports at three stadiums, namely Patriot Candrabhaga Stadium in Bekasi city, Wibawa Mukti Stadium in Bekasi regency, and Harapan Bangsa Stadium in Banda Aceh. However, this study focuses only on survey data from Wibawa Mukti Stadium in Bekasi regency, West Java, due to its similar spectator capacity and electrical system. Subsequently, a redesign of the electrical system was carried out by implementing the BGH concept. After the construction phase based on the electrical system design following the BGH principles was completed, The author conducted a check on electricity usage to understand electricity consumption after the renovation. Based on the author's observations, electricity consumption before and after implementing the BGH concept showed a significant decrease. Electricity consumption before the improvements was recorded at an Active Power of 13,227.36 kWh and a Reactive Power of 10,251.15 kVARh. Meanwhile, after the improvements, electricity usage showed an Active Power of 5,926.85 kWh, and Reactive Power was not calculated because the cos phi value of 0.93 exceeded the minimum penalty limit set by PLN at 0.85. There was an electricity savings of 7,300.51 kWh in one month, which means a 55% savings in kWh payments and 100% in kVARh payments. This indicates that the implementation of the BGH concept can effectively reduce electricity consumption in a building, which in turn will contribute to reducing the load on conventional power plants reducing the burden on conventional power plants that are not environmentally friendly.