Android-Based Smart Centrifuge with PID Speed Control Roichatun Nashichah; Deenda Putri Duta Natalia; Muhammad Kashif
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 13 No 2 (2026): Jurnal Ecotipe, October 2026
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/jurnalecotipe.v13i2.4605

Abstract

This study aimed to design and implement an Android-based centrifuge monitoring system with Proportional Integral Derivative (PID) speed control to improve rotational speed stability and monitoring flexibility in laboratory applications. The system utilized a DC motor as the driving unit, a speed sensor for feedback acquisition, and an Android application developed using MIT App Inventor for real-time monitoring. PID parameters were determined using the Ziegler–Nichols open-loop tuning method based on the process reaction curve. From the experimental response, a dead time of 0.5 s and a time constant of 3.65 s were obtained, resulting in PID parameters of Kp = 8.76, Ki = 8.76, and Kd = 2.19. Experimental testing was performed using a tachometer to evaluate rotational speed performance. The results showed that the implemented PID controller provided stable speed regulation with improved response characteristics and low steady-state error. In addition, the Android application successfully displayed real-time operational data and maintained reliable communication with the centrifuge system. The proposed system demonstrated that the integration of PID control and Android-based monitoring can enhance both control accuracy and operational convenience for laboratory centrifuge applications.
Development and Diagnostic Performance Evaluation of a Wireless Digital Fetal Heart Rate Monitoring System Using Ultrasonic Doppler with Digital Filter-Based Noise Reduction Muhammad Ridha Makruf; Roichatun Nashichah; Lusiana; Verry Angriawan
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 13 No 2 (2026): Jurnal Ecotipe, October 2026
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/jurnalecotipe.v13i2.4607

Abstract

Early fetal heart rate (FHR) monitoring is essential for assessing fetal well-being and enabling the early detection of fetal distress during pregnancy. However, existing fetal Doppler systems commonly rely on wired communication and remain susceptible to signal noise, limiting monitoring flexibility and measurement reliability. This study aimed to develop and evaluate a wireless fetal heart rate monitoring system with enhanced signal quality and reliable real-time communication. The proposed system integrates an ultrasonic Doppler sensor, ESP32 microcontrollers communicating through the ESP-NOW protocol, and digital signal processing using a Butterworth low-pass filter and a smoothing algorithm to suppress noise and improve signal clarity. System performance was evaluated using sampling frequencies ranging from 200 to 1000 Hz and baud rates from 300 to 250,000 bps. Communication reliability was assessed by transmitting 1,500 ADC packets for each sampling-frequency configuration and 1,000 ADC packets for each baud-rate configuration while monitoring packet sequence numbers to identify transmission loss. Experimental results showed that no packet loss was observed under all tested configurations. The developed system achieved BPM measurement errors ranging from 0.56% to 0.89% and improved signal quality, with the highest signal-to-noise ratio of 18.70 ± 0.17 dB obtained using a 0.5–20 Hz Butterworth filter. Higher sampling frequencies produced more detailed waveform representations, whereas higher baud rates improved transmission responsiveness without affecting waveform integrity within the tested range. These findings demonstrate that the proposed system provides an accurate, reliable, and portable solution for real-time wireless fetal heart rate monitoring.