Perbandingan Kebutuhan Rasio Tulangan Kolom dan Balok Bangunan Gedung KAI Boutique Hotel Bandung Akibat Beban Gempa dan Beban Gravitasi Nanang Chosim; Reynaldo Pratama Intan; Shofwan Donny Cahyono
Jurnal Civil Engineering Study Vol. 6 No. 02 (2026): Jurnal Civil Engineering Study
Publisher : Civil Engineering of Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study examines the comparison of reinforcement ratio requirements for beam and column components in the KAI Boutique Hotel Bandung building under the influence of seismic and gravity loads. This evaluation is based on the high seismic risk in Bandung City due to the activity of the Lembang Fault, as well as the mandatory compliance with SNI 1726:2019 and SNI 2847:2019 regulations using the Special Moment Resisting Frame System (SMRFS). Analysis was conducted through 3D structural modeling using finite element software to calculate the theoretical reinforcement area requirements, while maintaining fixed concrete cross-sectional dimensions in accordance with the project working drawings. Parameter comparison was reviewed based on the total weight of reinforcement steel volume (kg) between building floors to provide a quantitative overview from the owner's perspective. The results of the analysis indicate that the total reinforcement volume under seismic loads is 175,710.62 kg, whereas under pure gravity loads it is 114,667.73 kg. Overall, the integration of lateral seismic loads increases the reinforcement steel volume requirement by an average of 53.23% compared to gravity loads alone, with the most significant ratio difference detected on the 5th floor with a volume increase of 70.11% due to the substantial effect of the cumulative lateral base shear force.