Claim Missing Document
Check
Articles

Found 3 Documents
Search

An Alternative For New Road Embankment At Belanti Ex-Plg Food Estate Area, Pulang Pisau Regency – 3 (Case Study: Sta. 4+600 – Sta. 4+910 (Segment 1) and Sta. 0+000 – Sta. 0+065 (Segment 2)) Darma Karya Dika; Noor Endah Mochtar; Riwanto Marbun
Journal of Infrastructure & Facility Asset Management Vol 5 No 2 (2023): Journal of Infrastructure & Facility Asset Management
Publisher : Departemen Teknik Sipil, Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/jifam.v5i2.7676

Abstract

Oneof the lands used for the Food Estate program is a former peat land project, which is the Food Estate Area of the former PLG (PLG; proyek lahan gambut) of Belanti, Pulang Pisau Regency. In Sta 5+116, there is a market which makes road widening or the creation of road shoulder especially challenging. Therefore, the local government proposed to make an alternative route. The compression calculation analysis results in the first year, there is a settlement of 10.053 cm/year. Referring to MDP 2017, improvements need to be made by adding wood piles, or cerucuk, into the subgrade. Another soil improvement method is by using foam mortar, namely base and subbase; the qtimb of the baseis 2.4 kN/m2and the qtimb of the subbaseis 3.9 kN/m2for γaverage = 7 kN/m3and φaverage of 42.5°. The analysis of settlement time shows 3.6 mm/year, while the last step, which is the hydrostatic force analysis, revealed that foam mortar has a safety factor of 4.507, i.e., all have fulfilled existing requirements and are considered safe.The soil improvement method used to remove compression of subgrade employed wood piles, or cerucuk. The dimension of the cerucuk used is 10 cm for the diameter and 5 m for the depth,and the required number of cerucuk is 77. In order to reduce the subgrade compression, foam mortar was used as a road embankment material with consolidation compression occurring in the subgrade being 7,179 cm.
Alternative Design of Drive Pile and Floating Foundation of Bridge Structure over Soft Soil (Case Study : Muara Tahai Bridge Sta. 0+100 Kabupaten Pulang Pisau, Center Kalimantan) Asrul Mariadi; Noor Endah Mochtar; Riwanto Marbun
Journal of Infrastructure & Facility Asset Management Vol 5 No 2 (2023): Journal of Infrastructure & Facility Asset Management
Publisher : Departemen Teknik Sipil, Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/jifam.v5i2.7677

Abstract

One of the PSN progarm is the improvement of Muara Tahai Bridge that located in Kabupaten Pulang Pisau. The existing design of the substructures uses steel piles with a diameter of 50 cm and a depth of 28 meters due to soft soil condition. After a few trial, the effective design using piles can be done with the depth 20 meter with Pmax control of 34.65 tons < P allowed for group piles of 41.81 tons. An alternative design as a substructure is using floating foundation, which is concrete foundation using floaton material in it. The floating foundation dimension is 10 meter long, 3.2 meter width and 1,5 meter thick. The bearing capacity of the floating foundation using Terzaghi theory is 5,02 Ton/m2.
Alternative Studies Abutment Structure and Bridge Oprit on Soft Soil at Belanti Food Estate Area, Pulang Pisau Regency, Central Kalimantan (Case Study : Muara Tahai Bridge Sta. 0+100) Asrul Mariadi; Noor Endah Mochtar; Riwanto Marbun
Journal of Infrastructure & Facility Asset Management Vol 5 No 2 (2023): Journal of Infrastructure & Facility Asset Management
Publisher : Departemen Teknik Sipil, Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/jifam.v5i2.7678

Abstract

One of the PSN progarm is the improvement of Muara Tahai Bridge that located in Pulang PisauRegency. The existing design of the substructures uses steel piles with a diameter of 50 cm and a depth of 28 meters due to soft soil condition. After a few trial, the effective design using piles can be done with the depth 20 meter with Pmax control of 34.65 tons < P allowed for group piles of 41.81 tons. An alternative design as a substructure is using floating foundation, which is concrete foundation using floaton material in it. The floating foundation dimension is 10 meter long, 3.2 meter width and 1,5 meter thick. The bearing capacity of the floating foundation using Terzaghi theory is 5,02 Ton/m2.