Perbaikan Kurva Beban Harian pada Industri Kecil: Studi Kasus PT. X Arka D. Soewono; Dimas Kelvin; Karel Octavianus Bachri
Jurnal Elektro Vol 17 No 1 (2024): Jurnal Elektro: April 2024
Publisher : Program Studi Teknik Elektro, Fakultas Biosains, Teknologi, dan Inovasi, Universitas Katolik Indonesia Atma Jaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25170/jurnalelektro.v17i1.5404

Abstract

This paper presents the improvement of daily load and load balance curve of home-scale garment industry with the study case in PT. X. Research is started with load measurement on every machine, proceeded by plotting schedule of each machine. The next step is rescheduling daily load and per-phase load balancing. Initial data shows unbalance load sharing between phase with the average load of 4916 kW and standard deviation of 2077. After being rescheduled and phase rearrangement, the interphase load sharing is more balance, with the average load of 4903 kW and standard deviation of 952.
Implementasi dan Analisis Alat Kompres Demam Suhu Hangat dengan Sensor DS18B20 dan Pengendali Arduino Uno Karel Octavianus Bachri; Arka Soewono; Kevin
Jurnal Elektro Vol 17 No 2 (2024): Jurnal Elektro: Oktober 2024
Publisher : Program Studi Teknik Elektro, Fakultas Biosains, Teknologi, dan Inovasi, Universitas Katolik Indonesia Atma Jaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25170/jurnalelektro.v17i2.5626

Abstract

Fever is a condition where the body temperature rises above normal levels, often caused by an infection. Non-medical management of fever can be done by using cold or warm compresses. Warm compresses are more effective but require a complex and repetitive process. This study is the design of a Digital Fever Compress Device using warm temperature based on Arduino Uno. The Digital Fever Compress Device is designed for non-medical fever management. The Digital Fever Compress Device is equipped with a DS18B20 sensor, Liquid Crystal Display (LCD), Relay, cartridge heater as a heating element, three pushbuttons, XL4005 stepdown module, and one On-Off switch. The Digital Fever Compress Device can produce warm temperatures and adjust them according to the user's preferences with a minimum limit of 37.5°C and a maximum of 42°C with a timer for 20 minutes. Environmental temperature affects the temperature setting processing carried out by the microcontroller. Based on the tests conducted in an air-conditioned room, the average time from the initial temperature to the setpoint is 6 minutes and 15 seconds, and the temperature increase from the setpoint ranges from 45.6°C or 15.079%. Meanwhile, testing in a non-air-conditioned room, the average time from the initial temperature to the setpoint is 2 minutes and 26 seconds, and the temperature increase from the setpoint ranges from 44.64°C or 12.37%.
Frequency Extraction of Phonocardiogram Signal using Fourier Transform Karel Octavianus Bachri
Jurnal Elektro Vol 17 No 2 (2024): Jurnal Elektro: Oktober 2024
Publisher : Program Studi Teknik Elektro, Fakultas Biosains, Teknologi, dan Inovasi, Universitas Katolik Indonesia Atma Jaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25170/jurnalelektro.v17i2.6195

Abstract

This article presents Fourier Transform application to extract features of Phonocardiogram Signals into its frequency components. Data was taken from Physionet Dataset of Phonocardiogram which comprises of normal and abnormal heart condition. Raw data was preprocessed using time clipping of 2 seconds at certain area that contains less noise. A lowpass filter was applied to denoise the raw signals. Experiments show the PCG of normal hearts has a dominant frequency of 50Hz to 150Hz, with the subdominant frequencies of 450 Hz to 650 Hz. The subdominant frequency of the normal hearts sometimes show anomaly with more amplitude compared to the dominant frequency.