The urgency of this research stems from the pressing need to address the limitations of static air quality monitoring systems, especially given a 30% increase in respiratory complaints among Indonesian students by 2025 due to undetected hazardous pollutants. Employing a prototyping approach, the system integrates an MQ-135 gas sensor outputting raw analog voltage converted to parts per million (PPM), a DSM501A dust sensor outputting pulse width modulation (PWM) low-pulse occupancy ratio converted to micrograms per cubic meter (µg/m3), and an autonomous 18650 Li-ion battery management system with an MT3608 boost converter to ensure voltage stability. Furthermore, it utilizes an SSD1306 OLED display for independent, real-time data visualization without requiring internet connectivity. Field testing of this handheld device was conducted across 3 distinct indoor and outdoor test locations over a period of 3 consecutive days between 08:00 and 19:00 WIB. The air quality status was classified using a threshold-based procedure, categorizing conditions into "GOOD," "MODERATE," or "POOR" based on specific gas concentration and dust density ranges. The results showed significant daily fluctuations, with gas concentrations averaging 1,180 PPM (ranging from 450 to 2,300 PPM) and dust density averaging 44.2 µg/m3 (ranging from 12 to 95 µg/m3). The data demonstrated a clear trend where pollution peaked at 15:00, reaching a "POOR" air quality status during peak mobility hours, before gradually declining to a "GOOD" status by 19:00. Ultimately, this portable solution successfully maps air quality in previously inaccessible blind spots, providing functional monitoring data to help communities mitigate respiratory health risks.