Mohamad Joe Pratama
Program Studi Teknik Sipil Universitas Muhammadiyah Sidoarjo

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

Planning of the wastewater treat Planning of the wastewater treatment pond wall using reinforced concrete in the Taman Pinang, Sidoarjo: Planning of the wastewater treatment pond wall using reinforced concrete in the Taman Pinang, Sidoarjo Perencanaan dinding kolam IPAL menggunakan beton bertulang Pada Tempat Cuci Mobil di Kawasan Taman Pinang, Sidoarjo Mohamad Joe Pratama; Hendri Hermawan
Procedia of Engineering and Life Science Vol. 10 No. 1 (2026): Proceedings of the 9th Seminar Nasional Sains 2026
Publisher : Universitas Muhammadiyah Sidoarjo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21070/e944qz03

Abstract

General Background Vehicle washing operations generate wastewater containing sludge, oil, and detergents that can pollute urban environments if discharged without treatment. Specific Background Wastewater treatment plant ponds must provide watertight containment and resist internal fluid loads during continuous operation at car wash facilities in Taman Pinang, Sidoarjo. Knowledge Gap Practical structural planning for compact car wash wastewater pond walls under hydrostatic loading and reinforcement detailing requires clear documentation alongside broader tank and retaining structure studies. Aims This study plans reinforced concrete wastewater treatment pond walls for a car wash in Taman Pinang, Sidoarjo, by analyzing hydrostatic pressure and reinforcement requirements. Results For a rectangular pond of 3.0 m length, 1.2 m width, and 1.4 m height (1.2 m operating water depth) using fc' 20 MPa concrete, fy 240 MPa steel, and 10 cm wall thickness, hydrostatic calculation yields a base pressure of 14 kN/m², a horizontal resultant of 9.8 kN/m, a maximum moment of 4.57 kNm/m, an effective depth of 45 mm, a required steel area of approximately 485 mm², and vertical reinforcement of Ø10 at 150 mm spacing alongside horizontal reinforcement of Ø8 at 200 mm spacing. Novelty This work presents case-specific structural sizing and reinforcement calculations for a 10 cm reinforced concrete car wash wastewater pond wall in Taman Pinang, Sidoarjo. Implications The resulting wall thickness and reinforcement layout support safe and practical construction of wastewater containment walls at car wash facilities. Key Findings Highlights Hydrostatic triangular pressure analysis yields a maximum base pressure of 14 kN/m², a lateral resultant of 9.8 kN/m, and a maximum bending moment of 4.57 kNm/m. With a 10 cm wall thickness and 45 mm effective depth, required reinforcement reaches roughly 485 mm² and is specified as Ø10 at 150 mm vertically and Ø8 at 200 mm horizontally. Structural sizing with fc' 20 MPa concrete and fy 240 MPa reinforcement provides a practical reference for watertight car wash treatment ponds. Keywords Wastewater Treatment Plant, Reinforced Concrete, Pond Wall, Hydrostatic Pressure, Structural Design