Introduction: Accurate non-invasive characterisation of focal liver lesions (FLLs) determines whether patients proceed to surveillance, biopsy, or treatment. Contrast-enhanced ultrasound (CEUS) offers real-time, radiation-free, purely intravascular imaging, whereas magnetic resonance imaging (MRI) provides multiparametric soft-tissue contrast but is costlier, slower, and less available. Head-to-head evidence comparing the two modalities, particularly within the Liver Imaging Reporting and Data System (LI-RADS) framework, remains fragmented. We aimed to compare the diagnostic accuracy of CEUS and MRI for the characterisation of FLLs. Methods: This review followed PRISMA-DTA and was registered in PROSPERO (CRD420261514484). PubMed, Europe PMC, and ClinicalTrials.gov were searched to 13 November 2026, supplemented by citation searching. Diagnostic accuracy studies (including sub-analyses of randomised trials and primary observational studies) of adults with FLLs that evaluated CEUS against a reference standard, preferably with paired MRI, were eligible. Risk of bias was assessed with QUADAS-2 and, for comparative studies, QUADAS-C. Sensitivity and specificity were pooled with a bivariate binomial–normal generalised linear mixed model; summary receiver operating characteristic (SROC) curves were derived from the hierarchical model, and CEUS was compared with MRI-based imaging using bivariate meta-regression on paired data. Positive and negative predictive values (PPV, NPV), likelihood ratios (LR+, LR−), diagnostic odds ratios (DOR), area under the SROC curve (AUC), and accuracy of lesion characterisation were estimated. Certainty was graded with GRADE for test accuracy. Results: Nine studies (2,408 lesions) were included; seven provided paired CEUS and MRI-based (contrast-enhanced MRI or combined CT/MRI LI-RADS) data. CEUS yielded a summary sensitivity of 0.823 (0.754–0.876), specificity of 0.931 (0.881–0.961), LR+ of 11.97 (6.97–20.57), LR− of 0.190 (0.136–0.265), DOR of 63.0 (34.5–114.9), and an AUC of 0.944. Pooled PPV and NPV of CEUS were 0.948 (0.906–0.972) and 0.747 (0.597–0.856), and overall accuracy was 0.854 (0.804–0.892). MRI-based imaging achieved a sensitivity of 0.768 (0.653–0.854), specificity of 0.919 (0.811–0.968), and AUC of 0.906. In paired studies, CEUS and MRI-based imaging did not differ in sensitivity (relative sensitivity 1.03 (0.90–1.16)) or specificity (relative specificity 1.01 (0.98–1.05)); bivariate meta-regression showed no modality effect (likelihood-ratio test P = 0.91). For non-HCC malignancy, CEUS LR-M was more sensitive but less specific than CT/MRI LR-M (pooled PPV 0.34 vs 0.84). Leave-one-out estimates for CEUS remained within 0.80–0.84 for sensitivity and 0.92–0.94 for specificity; Deeks' test showed no small-study effect for CEUS (P = 0.66). Certainty was moderate for CEUS specificity, low for CEUS sensitivity, and low to very low for comparative estimates. Discussion: CEUS combines high specificity with moderate sensitivity, so a positive (LR-5 or malignant) CEUS result substantially raises the probability of the target condition, whereas a negative result does not reliably exclude it. Its accuracy is statistically indistinguishable from MRI-based LI-RADS in the same lesions, although heterogeneity, threshold effects in MRI studies, verification and incorporation bias, and the frequent pooling of CT with MRI limit inference. CEUS LR-M over-captures hepatocellular carcinoma (HCC), while CT/MRI LR-M is more specific for non-HCC malignancy. Conclusion: CEUS is a valid, safe, and accessible alternative and complement to MRI for characterising FLLs, with comparable sensitivity and specificity, and is particularly useful as a problem-solving tool for indeterminate observations. Prospective, adequately powered, fully paired studies using MRI alone as comparator and uniform reference standards are required.