OPTIMALISASI KINERJA ALAT X-RAY PHILLIPS OPTIMUS RAD ROOM: PENGABDIAN MASYARAKAT UNTUK MENDUKUNG LAYANAN KESEHATAN BERKELANJUTAN Amrullah, Rizky
Jurnal Pengabdian Multidisiplin dan Pemberdayaan Masyarakat Vol 1 No 2 (2024): ABDIKES TRADA : JURNAL PENGABDIAN MULTIDISIPLIN DAN PEMBERDAYAAN MASYARAKAT
Publisher : LPPM POLBITRADA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59485/abdikestrada.v1i2.88

Abstract

Kegiatan pengabdian masyarakat ini bertujuan memperbaiki alat X-Ray merek Phillips tipe Optimus RAD Room di Rumah Sakit Paru Dr. Ario Wirawan yang mengalami kerusakan pada beberapa komponen utama, yaitu Break pada Stand Rel (service board yang mensuplai tegangan), tombol arah pada kolimator, Fuse, dan Relay unit. Metode pelaksanaan meliputi identifikasi kerusakan menggunakan alat uji elektronik, perbaikan dan penggantian komponen yang rusak, pengujian fungsi alat pasca-perbaikan, serta pelatihan teknisi rumah sakit untuk meningkatkan kapasitas pemeliharaan mandiri. Hasil menunjukkan peningkatan signifikan pada performa alat, termasuk stabilitas suplai tegangan, responsivitas pengaturan kolimator, serta keamanan operasional dengan mengganti komponen protektif seperti Fuse dan Relay. Alat kembali berfungsi secara optimal, menghasilkan gambar radiografi yang lebih akurat, dan mendukung pelayanan medis yang lebih efisien. Kegiatan ini juga menekankan pentingnya pemeliharaan berkala dan kolaborasi antara institusi akademik dengan fasilitas kesehatan untuk memastikan keberlanjutan layanan. Keberhasilan program ini menjadi model yang dapat direplikasi di fasilitas kesehatan lain dengan kondisi serupa.
OPTIMALISASI SISTEM GROUNDING PADA FASILITAS DPPU YIA: STUDI KASUS DAN REKOMENDASI PERBAIKAN Amrullah, Rizky; Kuspranoto, Abdul Haris
Jurnal Pengabdian Multidisiplin dan Pemberdayaan Masyarakat Vol 1 No 2 (2024): ABDIKES TRADA : JURNAL PENGABDIAN MULTIDISIPLIN DAN PEMBERDAYAAN MASYARAKAT
Publisher : LPPM POLBITRADA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59485/abdikestrada.v1i2.90

Abstract

Activities The grounding system is an important component in electrical installations, especially in high-risk facilities such as Aircraft Filling Depots (DPPU). This study aims to evaluate the grounding system at DPPU Yogyakarta International Airport (YIA), including fuel tanks, pumps, generators and lightning rods, and provide recommendations to improve its reliability. Measurements were carried out using the straight line stretch method (0–5m–10m) according to PUIL 2000 and SNI 04-6918-2002 standards. The results show that most facilities have resistance below 5 ohms, such as tanks (0.74–0.88 ohms), LDP pumps (0.96–0.97 ohms), generators (0.97 ohms), and diesel pumps (1.16 ohms). The grounding system at this facility is considered adequate and safe for operations. However, the resistance of the lightning rod reached an average of 219 ohms, well above the standard limit. Pole damage due to corrosion and the possibility of broken grounding cables are the main causes of high resistance. This condition poses a high risk to safety and needs to be repaired immediately. The recommendations put forward include replacing lightning protection poles, reinstalling grounding cables, as well as additional protection for grounding cables at other facilities to prevent operational damage. Regular maintenance and periodic inspections are also recommended to maintain the performance of the grounding system in the long term. Most of the grounding systems at DPPU YIA meet national standards, immediate repairs to the lightning rods are necessary to improve the safety and reliability of the facility. These findings can be a reference for optimizing grounding systems in similar facilities.