This Author published in this journals
All Journal Bina Teknika
Pati, Gennady Chitra
Unknown Affiliation

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

Pengujian Pengaruh Ketinggian Weir pada Koefisien Discharge dari Weirmeter Sharp-Crested V-Notch 90o Komarudin, Komarudin; Suprijatmono, Djoko; Pati, Gennady Chitra
Bina Teknika Vol 15, No 1 (2019): Bina Teknika
Publisher : Fakultas Teknik UPN "Veteran" Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (777.444 KB)

Abstract

Weirmeter is a discharge gauge on an open-channel flow that is usually applied to dams and rivers. In each weirmeter there is a discharge coefficient (Cd), which is the coefficient multiplied by the theoretical discharge to obtain the actual discharge because the pressure difference and flow velocity are neglected. The Cd is directly proportional to the discharge. The actual debit measurement results do not approximate the result (the multiplication of the theoretical debit with Cd). This difference may be due to unequal Cd values for each weir dimension, one of which is the weir height (P). Therefore it is necessary to test the weirmeter with P varies in order to know the pattern and the value of Cd. The tested weirmeter is sharp-crested v-notch 90o with a length of 200 cm and a width of 35.5 cm. P used is 20.3 cm; 21.3 cm; and 22.3 cm. From the test, the Cd value is inversely proportional to P although some of these test results are far from the theory because it requires a 90% confidence interval on the Student distribution (t distribution). The value of Cd in weirmeter used is 0.6996 for P 20.3 cm; 0.6657 for P 21.3 cm; and 0.5781 for P 22.3 cm.