Claim Missing Document
Check
Articles

Found 2 Documents
Search

Interpersonal approach to the ability to check pregnancy with peb pregnant women in Kedunglangkap Hamlet Yuliani, Ika; Setyowati, Lisus; Ernawati, Iit
International Journal of Nursing and Midwifery Research Vol. 2 No. 1 (2023): November: Nursing and Midwifery Research
Publisher : Institute of Accounting Research and Novation (IARN)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35335/ners.v2i1.192

Abstract

Ante Natal Care (ANC) is the administration of health checks provided to mothers during their pregnancies according to antenatal check guidelines.  The aim of this research was to and the impact of interpersonal approach to agreement of antenatal care on expectants with eclampsia in Kedunglankap. This research used pre experimental design with pre-post test one group design. The sample were 34 expectants by total sampling and used Wilcoxon test to find the result . The results research the respondents who agreed to get antenatal care were 19 respondents (55.9%). Then who didn’t agree were is 15 respondents (44.1%), who greed to get antenatal care increasing to 29 respondents (85.3%). And didn’t agreed being 5 respondents (14.7%). Wilcoxon test o this research got the result if p value <0,005(p=0,002), which undicatedif there was an effectiveness of  personal app to antenatal care agreement of expectants with eclampsia in Kedunglangkap. Great expectations if midwives will always upgrade the knowledge and skill on giving antenatal and increasing interpersonal app on communication to patients.
PENURUNAN BOD dan TSS PADA LIMBAH INDUSTRI SAUS SECARA ELEKTROKOAGULASI MENGGUNAKAN ELEKTRODA Fe, Cu dan STAINLESS Yuliani, Ika; alimuddin, Alimuddin; Akkas, Erwin
JURNAL ATOMIK Vol 2 No 1 (2017)
Publisher : Jurusan Kimia FMIPA UNMUL

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (264.863 KB)

Abstract

Research about decreasing of BOD and TSS from waste in ketchup industry with Electrocoagulation method using Fe, Cu and Stainless electrode for decreasing BOD and TSS have been done. Time optimization based by color transformation from Electrocoagulation process have been done. The result of this research from the effect of time contact on Electrocoagulation process are showed the optimized time are 120 minutes whereas the transformation color into transparent color in 12 Volt using Fe-Cu electrode to the decreasing of BOD and TSS are 1800,6 mg/L ; 190 mg/L with the result of percent of elimination are 38,45% ; 68,85% whereas the value of starter of BOD and TSS are 2925,4 mg/L ; 190 mg/L.