Claim Missing Document
Check
Articles

Found 2 Documents
Search

PENERAPAN BALANCED SCORECARD SEBAGAI TOLAK UKUR PENGUKURAN KINERJA PADA ORGANISASI NIRLABA Arofah, Dewi; Priyadi, Maswar Patuh
Jurnal Ilmu dan Riset Akuntansi (JIRA) Vol 6, No 8 (2017)
Publisher : STIESIA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRACTThis research is aimed to test and to analyze the performance of RA. Basoeni Regional General Hospitals Mojokerto based on learning and growth perspective, internal business perspective, customer perspective and financial perspective by using the Balanced Scorecard method. The research objects are RA. Basoeni Regional General Hospitals Mojokerto in 2014 and 2015 which requires 80 patients and 50 employees as the respondents who have been selected by using purposive sampling. The data collection techniques have been done by performing preliminary survey, questionnaires, literary study, documentation, and interview. The method has been done by using descriptive qualitative analysis. The result of the research shows that RA. Basoeni Regional General Hospitals Mojokerto have had clear vision, mission, strategic goals and objectives. In 2014 and 2015 the average performance on learning and growth perspective is quite good since the numbers of employees decrease, the performance of the internal business perspective both when it is reviewed from inpatients in the surgery process, the performance on customer perspective because it shows patients satisfied with the provided services and perspective finances is better but it is still less economical in the use of the budget.Keywords: balanced scorecard, growth and learning perspective, internal business perspective, customer perspective and finance.
ANALISIS PERBANDINGAN AKURASI PENGUKURAN SUHU TUBUH MENGGUNAKAN SENSOR LM35 DAN MLX90614 Arofah, Dewi; Anwar, Khoerul; Setyowibowo , Sigit
Dinamika Dotcom : Jurnal Pengembangan Manajemen Informatika dan Komputer DINAMIKA DOTCOM Vol.16 No.1 Tahun 2025
Publisher : Sekolah Tinggi Manajemen Informatika & Komputer PPKIA Pradya Paramita Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The COVID-19 pandemic has increased the need for accurate body temperature measurement in public facilities. This study aimed to compare the accuracy of two types of temperature sensors, the LM35 and the MLX90614, for measuring human body temperature. Tests were conducted 36 times on adults, with a manufactured thermogun as the primary comparator. The results showed a significant difference in accuracy: LM35 sensor: Has an average error of 15.62% with an accuracy of 84.38%. This sensor operates based on linear voltage changes through direct contact with an object.MLX90614 sensor: Has an average error of only 1.17% with a high accuracy of 98.83%. The advantage of the MLX90614 lies in its ability to capture infrared light without physical contact, supported by a low-noise amplifier, 17-bit ADC, and the MLX90302 DSP unit, which the LM35 lacks. The conclusion is that the MLX90614 is far more effective and accurate for monitoring human body temperature.