A New Approach for Broken Bar Fault Detection in Three-Phase Induction Motor Using Instantaneous Power Monitoring under Low Slip Range Yassine Maouche; Mohamed El Kamel Oumaamar; Mohamed Boucherma; Abdelmalek Khezzar
International Journal of Electrical and Computer Engineering (IJECE) Vol 4, No 1: February 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (728.608 KB)

Abstract

The majority of research is about the detection of broken bar fault in three-phase induction motor at high slip. Thus, it becomes very interesting and demanding to detect faults in case of low slip range. In this study, a novel investigation of broken bar faults using instantaneous power is presented. The method is based on calculations and frequency analysis of partial and total instantaneous power under low slip range. The used model of squirrel cage induction machine takes into account the geometry and winding layout. This model will be used to analyze the impact of broken bar on instantaneous power spectrum. The proposed ideas in this paper are verified experimentally. The results show that broken bar fault can be more reliably detected under low slip range when using a large frequency area of both partial and total instantaneous power spectrums.DOI:http://dx.doi.org/10.11591/ijece.v4i1.4611