Saher Albatran
Jordan University of Science and Technology

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : International Journal of Electrical and Computer Engineering

Experimental Validation of Shared Inverter Topology to Drive Multi AC-Loads Saher Albatran; Issam A. Smadi; Mohammad A. Alsyouf
International Journal of Electrical and Computer Engineering (IJECE) Vol 8, No 2: April 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2821.8 KB) | DOI: 10.11591/ijece.v8i2.pp793-805

Abstract

Many reduced-switch-count (RSC) inverter topologies have been proposed in the literature. As the number of switches required to produce a set of voltages in RSC inverters are less than that in conventional inverter, as a result utilizing RSC inverters in a certain system reduces its size and cost. In this paper, a novel RSC shared inverter topology consisting of fifteen switches and capable of driving four three-phase AC-loads independently is proposed and experimentally verified. A carrier-based pulse width modulation (PWM) technique that employs the zero-sequence-signal injection principle is developed to drive the proposed inverter along with adequate DC voltage bus utilization between the shared loads for common frequency (CF) as well as different frequency (DF) modes. The structure and the principle of operation of the proposed inverter are introduced and intensively verified using simulation and field-programmable-gate-array (FPGA)-in-the-loop simulation under linear and nonlinear loads. Then, Inverter prototype was built and the proposed inverter has been verified experimentally. The experimental results verify the applicability of the proposed inverter and the employed PWM.
Enhanced dynamic performance of grid feeding distributed generation under variable grid inductance Salman Harasis; Saher Albatran; Eyad Almaita; Khaled Alzaareer; Qusay Salem; Mamdouh Alghaythi; Mohammad Arifur Rahman
International Journal of Electrical and Computer Engineering (IJECE) Vol 12, No 2: April 2022
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v12i2.pp1113-1122

Abstract

Controlling weak grid-connected systems is very challenging. In transient, frequency and voltage oscillations may lead to voltage and/or frequency stability problems and finally lead to system collapse. During steady-state operation and at the point of common coupling (PCC), voltage degradation and grid voltage background harmonics restrict the inverter's functionality, reduce the power flow capability and cause poor power quality. With weak grid connection, grid impedance variance will contaminate the voltage waveform by harmonics and augment the resonance, destabilizing the inverter operation. In this paper, complete mathematical modeling is carried out and state feedback-plus-integral control is implemented to support the stabilization of the system. The proposed controller is adopted to provide a smooth transient under sudden load change by controlling the injected grid current under different grid inductance values. Furthermore, the proposed control is used to reduce the order and size of the inverter output filter while maintaining system stability. The proposed control has been compared with the conventional proportional integral (PI) controller under different scenarios to validate its effectiveness and to strengthen its implementation as a simple controller for distributed generator applications.