Advanced SOM & K Mean Method for Load Curve Clustering Phan Thi Thanh Binh; Trong Nghia Le; Nui Pham Xuan
International Journal of Electrical and Computer Engineering (IJECE) Vol 8, No 6: December 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (373.834 KB) | DOI: 10.11591/ijece.v8i6.pp4829-4835

Abstract

From the load curve classification for one customer, the main features such as the seasonal factors, the weekday factors influencing on the electricity consumption may be extracted. By this way some utilities can make decision on the tariff by seasons or by day in week. The popular clustering techniques are the SOM & K-mean or Fuzzy K-mean. SOM &Kmean is a prominent approach for clustering with a two-level approach: first, the data set will be clustered using the SOM and in the second level, the SOM will be clustered by K-mean. In the first level, two training algorithms were examined: sequential and batch training. For the second level, the K-mean has the results that are strongly depended on the initial values of the centers. To overcome this, this paper used the subtractive clustering approach proposed by Chiu in 1994 to determine the centers. Because the effective radius in Chiu’s method has some influence on the number of centers, the paper applied the PSO technique to find the optimum radius. To valid the proposed approach, the test on well-known data samples is carried out. The applications for daily load curves of one Southern utility are presented.
A voltage electrical distance application for power system load shedding considering the primary and secondary generator controls Le Trong Nghia; Quyen Huy Anh; Phan Thi Thanh Binh; N Thai An; P. H. Hau
International Journal of Electrical and Computer Engineering (IJECE) Vol 9, No 5: October 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (860.717 KB) | DOI: 10.11591/ijece.v9i5.pp3993-4002

Abstract

This paper proposes a method for determining location and calculating the minimum amount of power load needed to shed in order to recover the frequency back to the allowable range. Based on the consideration of the primary control of the turbine governor and the reserve power of the generators for secondary control, the minimum amount of load shedding was calculated in order to recover the frequency of the power system. Computation and analysis of the voltage electrical distance between the outage generator and the loads to prioritize distribution of the amount power load shedding at load bus positions. The nearer the load bus from the outage generator is, the higher the amount of load shedding will shed and vice versa. With this technique, a large amount of load shedding could be avoided, hence, saved from economic losses, and customer service interruption. The effectiveness of the proposed method tested on the IEEE 37 bus 9 generators power system standard has demonstrated the effectiveness of this method.