Huzaimah Husin
Universiti Teknikal Malaysia Melaka

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

Design and Analysis of Capacitive Power Transfer System with and without the Impedance Matching Circuit F.K.A. Rahman; Shakir Saat; Yusmarnita Yusop; Huzaimah Husin; Y. Aziz
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 8, No 3: September 2017
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (947.169 KB) | DOI: 10.11591/ijpeds.v8.i3.pp1260-1273

Abstract

This paper presents the design and analysis of a relatively new wireless power transfer technique using capacitive coupling, named Capacitive power transfer (CPT). In general, CPT system has been introduced as an attractive alternative to the former inductive coupling method. This is because CPT uses lesser number of components, simpler topology, enhanced EMI performance and better strength to surrounding metallic elements. In this work, aluminium sheet is used as a capacitive coupling at transmitter and receiver side. Moreover, a Class-E resonant inverter together with π1a impedance matching network has been proposed because of its ability to perform the dc-to-ac inversion well. It helps the CPT system to achieve maximum power transfer. The CPT system is designed and simulated by using MATLAB/Simulink software. The validity of the proposed concept is then verified by conducting a laboratory experimental of CPT system. The proposed system able to generate a 9.5W output power through a combined interface capacitance of 2.44nF, at an operating frequency of 1MHz, with 95.10% efficiency. The proposed CPT system with impedance matching network also allows load variation in the range of 20% from its nominal value while maintaining the efficiency over 90%.
The Effects of Total Harmonics Distortion for Power Factor Correction at Non-Linear Load R. A. Rani; Shakir Saat; Yusmarnita Yusop; Huzaimah Husin; F. K. Abdul Rahman; A. A. Isa
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 7, No 2: June 2016
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v7.i2.pp551-560

Abstract

This paper presents the effect of total harmonic distortion (THD) in power factor correction (PFC) at non-linear load. This study focuses on the relationship between THD and PFC. This is beacuse,the power factor affects THD. This occurs in power system as we have variety of loads, i. e linear load or non-linear load. The variety of loads will influence the sinusoidal waveform, which comes out from harmonic distortion. Thus, based on this study, we can compare the effective method in improving the power factor as it will not disturb the performance of THD. The focus of study is on the single phase load, where the voltage restriction is 240 V.  The analysis will  only focus on the consumer, which depends on the variety of non-linear load. Besides, the parameters for analysis are based on the percentage of THD and the value of power factor. The instrument for measuring the parameter is based on power factor correction device or technique. On the other hand, the method that was used for this study is based on simulation which incorporated the Multisim software. At the end of ths study, we can choose the most effective method that can be used to improve the power factor correction without disturbing the THD.
Investigation of efficiency and safety in wireless capacitive power transfer through a single-layer tissue phantom Yusmarnita Yusop; Amy Sarah Ngu; Cheok Yan Qi; N. B. Asan; Huzaimah Husin; Shakir Saat; Peter Adam Hoeher
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 17, No 1: March 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v17.i1.pp502-517

Abstract

Wireless power transfer (WPT) is a promising solution for implantable biomedical devices, offering an alternative to traditional implanted batteries and percutaneous connections, which are limited by short lifespans and high infection risks. Existing capacitive power transfer (CPT) systems for biomedical implants often utilize media such as animal meat or liquids to validate power transfer across the human body, but these materials exhibit inconsistent and inaccurate dielectric properties. To address this limitation, this study proposes a CPT system designed to operate with a single-layer tissue phantom that closely mimics the dielectric characteristics of human tissue. The system is integrated with a class-E LCCL resonant topology to enhance power transfer efficiency. In addition to evaluating performance, this work also investigates safety aspects in terms of electric field emission and specific absorption rate (SAR). Simulations using MATLAB Simulink and ANSYS HFSS reveal that at a 1 mm tissue gap, the electric field reaches 298.09 V/m and the SAR is 1.14 W/kg, which are both within established safety limits (614 V/m and 2 W/kg per 10 g of tissue). Furthermore, a 5 W, 1 MHz system operating across a 2 mm tissue gap demonstrates power transfer efficiencies of 40.61% for skin tissue and 20.53% for muscle tissue. These results validate the system’s safety and efficiency for powering deeply implanted biomedical devices.