Proposed PV Transformer-Less Inverter Topology Technique for Leakage Current Reduction M. N. H. khan; M.H. Delwar; Md. A. Kabir; M.S. Zahan; K. J. Ahmad; M. M. Alam; M. T. Anower
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 7, No 3: September 2016
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v7.i3.pp936-945

Abstract

Importance and demand of using renewable energy is dramatically escalated globally. Hence, the use of renewable energy is going to touch in peak. This demand is varying according to the site choosing. For instance, Wind is preferable where air is following highly as well as solar recommended place is high sun ray reducing places. Especially, the renewable system is highly recommended for electrification issues where it’s possible to produce the electricity for fulfilling rural and remote areas electricity problem.  The photovoltaic (PV) panel of connecting with transformer based system is popular where some limitations are occurred especially cost and weight. In contrast, in this paper is focusing these issues where the transformer-less inverter system is used. Here will discuss some transformer-based and transformer-less inverter topologies and the leakage current issue which is occurred when transformer-less inverter system is used. Moreover, here is proposed a topology for reducing the leakage current after doing switching technique in both 50% and 75% duty cycle where output voltage remains quite same.
Battery-equivalent DC Supply from Leakage Current: PV to Transformer-less Inverter Topology M. N. H. Khan; K. J. Ahmad; M. S. Zahan; M. N. Hasan
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 7, No 4: December 2016
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v7.i4.pp1193-1199

Abstract

Solar panels are highly used for electricity generation, which can be gotten through switching-based transformer-less inverters. Hence, grid system with no galvanic-isolation, is taking the peak level in the world, which is effective and delivers power with enhanced efficiency. The PV generation presented here is for stand-alone system installed in remote areas on when and as the resulting power gets connected to electronic load installation instead of being tied to the grid. In this paper will be discussed the use of leakage current. Transformer-less inverter topology for exploring the issue of common mode (CMV) voltage development, which can be utilized as a Battery-Equivalent DC Supply after adding on places as when found suitable for such installations.
Performance Analysis of Non-Renewable Energy in Bangladesh M. G. Rabbani; C. T. Sattary; M. R. A. Mamun; M. M. Rahman; M. N. H. Khan
Indonesian Journal of Electrical Engineering and Computer Science Vol 5, No 2: February 2017
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v5.i2.pp290-298

Abstract

The demand of energy is dramatically increased nowadays and the demand either can renewable or non renewable depends on the drawbacks. Hence, non renewable energies show the better performance where the limitations are comprisable very few and environmental friendly. Already developed countries are being used renewable energies as the main sources of energy to produce electricity where it proved the less easy and more benefits. However, non renewable energies such as natural gas, gas generator and so on  still have been  producing more and more electricity and this amount is around 10 times more than renewable energies especially developing countries like Bangladesh. This paper is being discussed the importance of renewable energies and non renewable energies to produce electricity, comparing the different countries electricity production and the using sources. Here analysis the data of different power plants in Bangladesh and the types of fuel, CO2 emission and electricity production. In additionally, Gazipur district has been selected to show the power consumption factories with the cost analysis in selected fuel types.
Switching Algorithm for Leakage Current Reduction in a PV- No Transformer Inverter System M. N. H. Khan; M. R. Hasan; M. K. Alam
Indonesian Journal of Electrical Engineering and Computer Science Vol 4, No 1: October 2016
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v4.i1.pp52-56

Abstract

Electricity generation purposes renewable energy brings a important role especially Photovoltaic (PV) panels that can be covered our basic energy (electricity) needs. This photovoltaic panels cover a domestic level (solar power for home), commercially (solar power for commercial applications) or at the community level.  Here used this photovoltaic panel as an input of PV-transformer-less inverter topology which has been compared with existed H6 transformer-less inverter topology. It’s possible to reduce the leakage current with inclined the output voltage that has been shown here by using proposed topology.  This topology is made by using two extra switches with filter. Moreover, overall system actually verified with Pulse Width Modulation (PWM) switching technique.