A.R. Abdullah
Universiti Teknikal Malaysia Melaka

Published : 4 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 4 Documents
Search

An Improved of Multiple Harmonic Sources Identification in Distribution System with Inverter Loads by Using Spectrogram M.H. Jopri; A.R. Abdullah; M. Manap; M.R. Yusoff; T. Sutikno; M.F. Habban
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 7, No 4: December 2016
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v7.i4.pp1355-1365

Abstract

This paper introduces an improved of multiple harmonic sources identification that been produced by inverter loads in power system using time-frequency distribution (TFD) analysis which is spectrogram.  The spectrogram is a very applicable method to represent signals in time-frequency representation (TFR) and the main advantages of spectrogram are the accuracy, speed of the algorithm and use low memory size such that it can be computed rapidly. The identification of multiple harmonic sources is based on the significant relationship of spectral impedances which are the fundamental impedance (Z1) and harmonic impedance (Zh) that extracted from TFR. To verify the accuracy of the proposed method, MATLAB simulations carried out several unique cases with different harmonic producing loads on IEEE 4-bus test feeder cases. It is proven that the proposed method is superior with 100% correct identification of multiple harmonic sources. It is envisioned that the method is very accurate, fast and cost efficient to localize harmonic sources in distribution system.
An Evaluation of Linear Time Frequency Distribution Analysis for VSI Switch Faults Identification M.F. Habban; M. Manap; A.R. Abdullah; M.H. Jopri; T. Sutikno
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 8, No 1: March 2017
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v8.i1.pp1-9

Abstract

This paper present an evaluation of linear time frequency distribution analysis for voltage source inverter system (VSI). Power electronic now are highly demand in industrial such as manufacturing, industrial process and semiconductor because of the reliability and sustainability. However, the phenomenon that happened in switch fault has become a critical issue in the development of advanced. This causes problems that occur study on fault switch at voltage source inverter (VSI) must be identified more closely so that problems like this can be prevented. The TFD which is STFT  and S-transform method are analyzed the switch fault of VSI.  To identify the VSI switches fault, the parameter of fault signal such as instantaneous of average current, RMS current, RMS fundamental current, total waveform distortion, total harmonic distortion and total non-harmonic distortion can be estimated from TFD. The analysis information are useful especially for industrial application in the process for identify the switch fault detection. Then the accuracy of both method, which mean STFT and S-transform are identified by the lowest value of mean absolute percentage error (MAPE). In addition, the S-transform gives a better accuracy compare with STFT and it can be implement for fault detection system.
Harmonic Load Diagnostic Techniques and Methodologies: A Review A.S. Hussin; A.R. Abdullah; M.H. Jopri; T Sutikno; N.M. Saad; Weihown Tee
Indonesian Journal of Electrical Engineering and Computer Science Vol 9, No 3: March 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v9.i3.pp690-695

Abstract

This paper will review on the existing techniques and methodologies of harmonic load diagnostic system. The increasingly amount of harmonic producing load used in power system are the main contribution in quantifying each harmonic disturbance effects of the multiple harmonic producing loads and it became very important. Literature proposes two different techniques and methods on the harmonic source identification under the soft computing technique classification. The advantages and disadvantages of harmonic load identification techniques and methods are discussed in this paper. In the proposed method, the issue on the harmonic contribution is determine and transformed to a data correlation analysis. Several techniques to identify the sources of harmonic signals in electric power systems are described and reviewed based on previous paper. Comparative studies of the methods are also done to evaluate the performance of each techniques. However, without sufficient information in this inconsistent environment on the property of the power system, accurate harmonic producing load diagnosis methods are important and further investigations in this regard assumes great implication.
Automated Real-Time Vision Quality Inspection Monitoring System N.N.S. Abdul Rahman; N.M. Saad; A.R. Abdullah; M.R.M. Hassan; M.S.S.M Basir; N.S.M. Noor
Indonesian Journal of Electrical Engineering and Computer Science Vol 11, No 2: August 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v11.i2.pp775-783

Abstract

The requirement of product quality inspection in industries for product standardized leads to a development of the quality inspection system. The problem is related to a manual inspection that is done by a human as an inspector. This paper presents an automated real-time vision quality inspection monitoring system as a problem solver to a manual inspection that is tedious and time-consuming task as well as reducing cost especially in small and medium enterprise industries (SME). For the proposed system, soft drink is used as the test product for quality inspection. The system uses computer-network to inspect two quality inspections which are color concentration and water level. The analysis includes pre-processing, color concentration using the histogram and quadratic distance and level inspection using coordinate vertical and horizontal reference levels. The similarities of both experimental and simulation results are obtained for both parameters which are 100% accuracy using 205 samples.