Fady Wadie
Egyptian Russian University

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

A wide area fault detection algorithm for transmission networks equipped with series compensation units Mohamed A. Ebrahim; Fady Wadie; Mousa A. Abd-Allah
International Journal of Applied Power Engineering (IJAPE) Vol 8, No 1: April 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (617.976 KB) | DOI: 10.11591/ijape.v8.i1.pp49-60

Abstract

In this paper, a wide area back-up protection (WABP) algorithm is presented based on phasor measurement units (PMUs) measurements placed across the transmission network. The proposed algorithm computes a selected index named as positive sequence power index (PSPI) to detect faults in the network. Firstly, the network is subdivided into back-up protection zones. For each zone, the PSPI index is computed as absolute the value of the difference between the positive sequence sent and received phasor powers across the terminals of the zone. For each zone, the PSPI is compared to a predefined threshold to detect faults. One of the contributions in this paper is the usage of mathematical formulation to set the threshold values for each zone rather than experimental trials usually used in previous literature. In addition, the algorithm doesn’t depend iterative solutions nor line parameters of the network as usually used in WABP schemes. These advantages enhance the degree of confidence in decisions of the algorithm and reduces computational burdens to trivial amount. The presented algorithm (Level-1) could be enhanced into (level-2) if PMUs are available on all buses and in such case, the faulty line could be detected directly in a single step. WSCC 9-bus system and NE 39-bus systems were considered to accomplish this study. Severe cases for series compensated lines were taken into consideration including voltage or current inversion. Simulation results emphasis on algorithm’s robustness and adaptability.
Comparative analysis for different passive filter topologies in grid-tied PV systems Shorouk Elsayed Ibrahim Mehrez; Asmaa Sobhy Sabik; Fady Wadie; Ibrahim A. Nassar
Indonesian Journal of Electrical Engineering and Computer Science Vol 42, No 1: April 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v42.i1.pp1-12

Abstract

The enhancement of power quality in grid-connected photovoltaic (PV) systems requires the development of effective harmonic mitigation techniques. This paper addresses the design and evaluation of specific passive filters (RC, LC, and LCL filters) for a three-phase grid-tied PV system, aiming to mitigate harmonics in the power system. The paper also systematically calculates and optimally solves for the components required for the given system. The design of the parameters for all filter topologies within the 100-kW grid-connected PV array is thoroughly elaborated. Each topology is evaluated based on the total harmonic distortion (THD) content, which is obtained using fast fourier transform (FFT), as well as DC voltage and system efficiency. The results are presented to identify the best solutions for harmonic mitigation. The modified filter model demonstrated in this study effectively limits harmonic distortion at the output. It is shown that the proposed design addresses the issue of harmonic distortion in grid-connected inverters for PV systems. The goal of this paper is to identify the most reliable filter for extending the system’s lifespan. The results suggest that the LCL filter is superior, as the system’s DC voltage remained within the rated value and the system efficiency was higher compared to the RC filter. The performance and functionality of these filters were tested using MATLAB/Simulink.