A. Din
Universiti Teknikal Malaysia Melaka

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

Prediction of surface leakage current of overhead insulators under environmental and electrical stresses F. S. Abdullah; M. A. M. Piah; N. A. Othman; A. Din
Bulletin of Electrical Engineering and Informatics Vol 9, No 5: October 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (500.753 KB) | DOI: 10.11591/eei.v9i5.2182

Abstract

Leakage current is one of the critical aspects to consider for overhead transmission line insulator’s condition and performance assessment. As the leakage current increase, the size of the dry band also will increase leads to the dry band arcing, deteriorate the insulator performance and contribute to the development of insulator flashover. Based on the literature study, other than the existence of contaminations on the surface of insulator combined with moisture, the variation in leakage current is also affected by the environmental and electrical stresses. Previous researches have shown the effect of environmental and electrical stresses on surface leakage current based on experimental and simulation results. This paper outlines an analytical approach based on dimensional analysis to propose a new mathematical model of leakage current under environmental and electrical stresses. To justify the applicability of the derived dimensional model, the new model has been validated using previous researcher’s experimental results. The validation indicated that the proposed model had shown a good agreement with the previous experimental results. The proposed dimensional equation for this research work can be potentially used as a predictive performance model to evaluate and monitor the leakage current and insulator’s performance
Surface roughness condition of field-aged polymer insulators at different installation area A. Din; M.A. M. Piah; A. R. Abdullah; N. F. Kasri
Indonesian Journal of Electrical Engineering and Computer Science Vol 15, No 2: August 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v15.i2.pp600-608

Abstract

This paper presents surface degradation assessment based on surface roughness condition for various field-aged high voltage polymer insulators that were installed at different locations. The measurement of arithmetical mean surface roughness is done, and statistical analysis is implemented in this study. Three groups of insulators labeled as 6 years, 12 years, 18 years, and with their respective controlled samples are tested using a surface roughness tester. Data measurements from the testing are analyzed in conjunction with visual observation to investigate an indication of surface degradation within the groups. Further statistical analysis is applied for the comparison of the surface roughness conditions. In order to observe the environmental stress factors that will affect the roughness condition, within the installation area, the virtual three-dimensional mapping program represented the Earth based on satellite imagery is utilized. The correlation analysis on all that three groups has indicated the positive outcomes with the roughness increased with respect to the age of insulator that located in quite similar environmental stress conditions. Regardless of the age of an insulator, the degradation due to surface roughness condition can be used to indicate what levels of environmental stress around the installation area have.
Leakage current signal parameter of various surface roughness conditions of field-aged polymer insulators A. Din; M. A. M. Piah; A. R. Abdullah; N. Norddin; F. S. Abdullah
Indonesian Journal of Electrical Engineering and Computer Science Vol 20, No 2: November 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v20.i2.pp638-645

Abstract

This paper presents the signal parameter of leakage current based on various surface roughness degradation conditions for field-aged high voltage polymer insulators. The arithmetical mean of surface roughness is measured accordingly, and also the surface leakage current signal is captured effectively using data acquisition device via the electrical stress test. With the variation of field-aged insulators ages which include 6-year, 12-year and 18-year, they have been mechanically tested using a surface roughness tester along with electrical testing by using the standard method of inclined plane test. The surface roughness data are recorded meanwhile the leakage current signals are further analyzed using Spectrogram to extract the signal parameter. These include the instantaneous root mean squared current, the instantaneous total harmonic distortion, the instantaneous total non- harmonic distortion and the instantaneous total waveform distortion. From the results of the comparative study, it has shown that the statistical quantity of leakage current signal parameters is responding in an increasing trend with respect to the incremental of the surface roughness. Thus, the signal parameters of the leakage current are able to indicate the degradation conditions of insulator surface.