Claim Missing Document
Check
Articles

Found 3 Documents
Search
Journal : Medical Laboratory Technology Journal

Perbedaan Kadar Hemoglobin Metode Sianmethemoglobin dengan dan Tanpa Sentrifugasi pada Sampel Leukositosis wahdah norsiah
Medical Laboratory Technology Journal Vol. 1 No. 2 (2015): December
Publisher : Poltekkes Kemenkes Banjarmasin Jurusan Analis Kesehatan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1052.261 KB) | DOI: 10.31964/mltj.v1i2.19

Abstract

Examination of hemoglobin levels influenced leukocytosis sianmethemoglobin method that causes increased absorbance measurements of hemoglobin levels increased significantly and the false blood sample that has been diluted with a solution Drabkins in centrifugation at 3000 rpm for 10 minutes and then the absorbance of the supernatant was measured with a photometer at λ 546 nm. This study aimed to analyze the differences in hemoglobin level examination siamethemoglobin method with and without centrifugation at sample leukocytosis. This type of research is observational research laboratory. The study design was cross-sectional study. Samples were taken from the remaining blood samples of patients who have been examined leukositnya number more than 20,000 / uL with Hematology Analyzer (CEL-DYN Ruby) February-April 2014, and were divided into 4 groups based on criteria that group 1. leukocyte count of 20,000 / uL-29 999 / mL, group II. 30,000 / uL-39 999 / uL, the group III. 40,000 / uL-49,999 / uL, the group IV. More than 50,000 / uL. The number of samples taken were 20 samples of each group, a total sample of 80 samples. The analysis showed no significant difference in hemoglobin levels siamethemoglobin method with and without centrifugation at sample leukocytosis with a value of p = 0.000 less than 0.05 α. Leukocytosis Turbidity affects the difference in hemoglobin levels with and without centrifugation, the higher the number the greater the difference in leukocyte levels of hemoglobin, hemoglobin level examination results of the study based on the criteria of the number of leukocytes obtained by the difference in hemoglobin levels with and without centrifugation in group I. 0.22 ± 0.07 g / dL, group II 0.40 ± 0.22 g / dL, a group III. 0.44 ± 0.14 g / dL, Group IV. 0.85 ± 0.41 g / dL. The level of hemoglobin in the sample sianmethemoglobin method leukocytosis with more than 20,000 / uL need a centrifuge so that appropriate hemoglobin levels over the patient's clinical condition.
Immune Response to anti-HBs Antibodies in Health Workers Following Hepatitis B Vaccination Dinna Rakhmina; Wahdah Norsiah; Tini Elyn Herlina; Norhafizah Mulia Sari; Reza Pertiwi; Rizka Ariani; Sahri Rahman
Medical Laboratory Technology Journal Vol. 7 No. 2 (2021): December
Publisher : Poltekkes Kemenkes Banjarmasin Jurusan Analis Kesehatan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (313.363 KB) | DOI: 10.31964/mltj.v7i2.418

Abstract

According to Regulation No. 53 of 2015 of the Minister of Health of the Republic of Indonesia, a high risk of HBV infection in health workers is a problem that requires attention, and vaccination knowledge is critical to reducing these risk factors. Furthermore, because some people do not produce a sufficient antibody-forming (anti-HBs) response to HBsAg, testing for evidence of protective immunity against hepatitis B vaccination is required (Hepatitis B Surface Antigen). The purpose of the study was to determine the mapping of the characteristics of anti-HBs antibodies response after hepatitis B vaccination in health workers in terms of age, gender, ethnicity, smoking habits, obesity, vaccination frequency, last time of vaccination. Sixty vaccinated health workers were used to creating the research sample. Anti-HBs levels/titers in serum were measured using the Enzyme-Linked Immunosorbent Assay (ELISA) method, and a questionnaire was used to compile the data for this study. Age, gender, smoking, obesity, and vaccination dose were all used to map the outcomes of the anti-HBs antibody immune response study. Anti-HBs antibody response in health workers was graded as poor in 36 people (60%) and strong in 24 (40%). Regarding ethnic origin, lifestyle, obesity, and vaccination dose (frequency), there was no significant link between post-vaccination anti-HBs antibody response in health workers. In terms of age and gender, there is a strong association between post-vaccination anti-HBs antibody responses in health workers. Low antibody titers should be revaccinated to enhance anti-HBs titers, and health workers who smoke should quit because it reduces the levels of anti-HBs titers produced clinically.
Comparison of Clinical Assessment and Adhesive-Tape Laboratory Microscopic of Sarcoptes scabiei for Scabies Diagnostic Rifqoh Rifqoh; Wahdah Norsiah; Neni Oktiyani
Medical Laboratory Technology Journal Vol. 7 No. 1 (2021): June
Publisher : Poltekkes Kemenkes Banjarmasin Jurusan Analis Kesehatan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (302.653 KB) | DOI: 10.31964/mltj.v7i1.379

Abstract

Scabies infestation caused by Sarcoptes scabiei mite that infected the skin by making the tunnel burrow. Diagnosis of scabies infestation commonly relies on clinical assessment (CA). However, some scabies symptoms are similar to other diseases. Diagnosis of confirmed scabies can be made by identifying egg or Sarcoptes scabiei mite or scybala through skin scraping laboratory microscopic examination, which was the adhesive tape microscopic (AT) a noninvasive alternative. We aimed to compare the scabies diagnostic accuracy of CA and AT in Islamic Boarding School. This study was an analytical observational cross-sectional study. The population was 94 students of Islamic Boarding School, determining the sample base on purposive sampling technique. There were 34 samples with presumptive scabies analyzed with CA by two clinicians and AT by two trained laboratory technicians. The result showed that the number of patients who positive scabies by CA was 14 (41.18 percent) and 31 (91.18 percent) by AT. Sensitivity was 41.93 percent for CA and 92.85 percent for AT, and the difference was significantly based on Cohen's kappa (ⱪ=0.024). The number of positive cases with both techniques was 13 (38.24 percent). The number of patients positive with only CA was 1 (2.93 percent), and only AT was 18 (22.9 percent). The accuracy of CA was only 44,11 percent. The study concluded that CA is low accuracy than AT. The adhesive tape test is easy, needs no expensive equipment. It is recommended that adhesive tape test for screening purposes. The appropriate comprehensive of both methods for scabies diagnostic is highly recommended.