Claim Missing Document
Check
Articles

Found 4 Documents
Search

Tatalaksana Pemeriksaan Thorax Pada Bayi Dengan Kasus Berat Badan Lahir Rendah (BBLR) Di Instalasi Radiologi RS Islam Faisal Makassar Wahyuddin Wahyuddin; AR.Rakhmansyah Iskandar; Nur Halisa Tul Ma’rifa
Lontara Journal of Health Science and Technology  Vol 1 No 2 (2020): Ilmu dan Teknologi Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian Masyarakat Politeknik Kesehatan Muhammadiyah Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53861/lontarariset.v1i2.73

Abstract

LBW is one indicator to see how the degree or health status of children, so it plays an important role to monitor how the health status of children from birth. This study aims to find out how to administer Thorax Examination in Infants with a West Low Birth (BBLR) case at Faisal Makassar Islamic Hospital. In the research method, the writer uses qualitative research with a descriptive approach. From the results of the research conducted it can be concluded that the management of Thorax examination in infants with cases of Low Birth Weight (LBW) in Faisal Islamic Hospital Makassar Antero Posterior projection (AP) is said to be enough to optimally diagnose the doctor's reading results namely bilateral pneumonia.
Analisa Artefak Pada Hasil Radiograf Yang Timbul Akibat Pengolahan Computed Radiography Wahyuddin Wahyuddin; AR.Rakhmansyah Iskandar; Nurul Adilah Z.
Lontara Journal of Health Science and Technology  Vol 2 No 1 (2021): Ilmu dan Teknologi Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian Masyarakat Politeknik Kesehatan Muhammadiyah Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53861/lontarariset.v2i1.186

Abstract

Artefacts are structures or appearances that are not normally present on radiographs, errors in radiographic processing may be due to technical errors or film processing errors. This research was conducted using Descriptive methods, with the type of literature study that aims to examine the causes of artifacts that can occur as a result of improper handling of film processing errors.The results of the analysis concluded that the frequent occurrence of artifacts in the processing of Computed Radiography is caused by two factors, that is the use of imaging plates and grids lisolm. His advice should be in the processing using Computed Radigraphy the officer must be more careful and pay attention to the components in Computed Radiography.
Tatalaksana Pemeriksaan Thorax Pada Bayi Dengan Kasus Berat Badan Lahir Rendah (BBLR) Di Instalasi Radiologi RS Islam Faisal Makassar Wahyuddin Wahyuddin; AR.Rakhmansyah Iskandar; Nur Halisa Tul Ma’rifa
Lontara Journal of Health Science and Technology Vol 1 No 2 (2020): Ilmu dan Teknologi Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian Masyarakat Politeknik Kesehatan Muhammadiyah Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53861/lontarariset.v1i2.73

Abstract

LBW is one indicator to see how the degree or health status of children, so it plays an important role to monitor how the health status of children from birth. This study aims to find out how to administer Thorax Examination in Infants with a West Low Birth (BBLR) case at Faisal Makassar Islamic Hospital. In the research method, the writer uses qualitative research with a descriptive approach. From the results of the research conducted it can be concluded that the management of Thorax examination in infants with cases of Low Birth Weight (LBW) in Faisal Islamic Hospital Makassar Antero Posterior projection (AP) is said to be enough to optimally diagnose the doctor's reading results namely bilateral pneumonia.
Analisa Artefak Pada Hasil Radiograf Yang Timbul Akibat Pengolahan Computed Radiography Wahyuddin Wahyuddin; AR.Rakhmansyah Iskandar; Nurul Adilah Z.
Lontara Journal of Health Science and Technology Vol 2 No 1 (2021): Ilmu dan Teknologi Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian Masyarakat Politeknik Kesehatan Muhammadiyah Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53861/lontarariset.v2i1.186

Abstract

Artefacts are structures or appearances that are not normally present on radiographs, errors in radiographic processing may be due to technical errors or film processing errors. This research was conducted using Descriptive methods, with the type of literature study that aims to examine the causes of artifacts that can occur as a result of improper handling of film processing errors.The results of the analysis concluded that the frequent occurrence of artifacts in the processing of Computed Radiography is caused by two factors, that is the use of imaging plates and grids lisolm. His advice should be in the processing using Computed Radigraphy the officer must be more careful and pay attention to the components in Computed Radiography.