Effect of Temperature on pH Meter Based on Arduino Uno With Internal Calibration lilia wati dewi pratami; Her Gumiwang Ariswati; Dyah Titisari
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 1 (2020): January
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v2i1.5

Abstract

pH Meter is a device used to express the level of acidity or basicity possessed by a substance or solution. Normal pH has a value of 7 while the pH value> 7 indicates that the substance has alkaline properties while the pH value <7 indicates acidic properties. pH 0 shows a high degree of acidity, and pH 14 shows the highest degree of alkalinity. pH Meter reads the pH and temperature values ​​in a sample. The author uses glass electrodes as a pH sensor, DS18B20 as a temperature sensor and LCD to make pH and temperature values. This module is equipped with an internal calibration that is used to set the module to read the pH value properly and correctly using a pH buffer and equipped with internal storage and this module facilitates battery usage. Based on pH measurements on the module the error value in buffer 4 calibration is 5.39%, in buffer 7 is 1.76%, in buffer 10 is 1.04%. The highest error value in the measurement sample is 3.54% and the lowest error value is 0.03%. The temperature of the sample is very influential on the reading of the pH value because the higher the temperature the pH value also increases even though it is not so significant.
Digital Pressure Meter Equipped with Temperature and Humidity Abdul Cholid; Her Gumiwang Ariswati; Syaifudin Syaifudin
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 1 (2020): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i1.1

Abstract

Calibration is a technical activity which consists of the determination, the determination of one or more properties or characteristics of a product, process or service in accordance with a special procedure has been set. The purpose of which is to ensure the calibration measurement results in accordance with national and international standards. The tools used for the calibration of pressure Digital Pressure Meter. This tool is used to measure the pressure and suction pump spygnomanometer or other devices that use parameters for measuring pressure. This module manufacturing system using Arduino system as a controller and as processing analog data into digital data of the sensor MPX5100GP and MPXV4115V using analog signal conditioning circuit and displayed on the LCD Touchscreen with 2 modes of measurement that is positive pressure and vacuum pressure with pressures ranging from 0-300 mmHg for positive pressure and 0 –(-400) mmHg to vacuum pressure. There are also DHT22 sensor, As a detector for temperature and humidity for use in the work method in the calibration process. Based on a stress test generated and using comparators Digital Pressure Meter 2 plus brand fluke, this tool has an error value of 0 to 0.58% and has a value increment or correction value of 0 - 3. It can be concluded that the DPM DUA MODE this deserves to be used.