PELATIHAN PENGOPERASIAN DAN PERAWATAN MESIN PRODUKSI DENGAN KENDALI ELEKTRONIKA UNTUK PENGAJAR PROGRAM STUDI TEKNIK LISTRIK INDUSTRI DI SMK TUREN – KAB. MALANG Mochammad Mieftah; Awan Setiawan; Rachamad.S; M.Manaf; Anang Dasa Novfowan
Jurnal Pengabdian Polinema Kepada Masyarakat Vol. 7 No. 2 (2020): Jurnal Pengabdian Polinema Kepada Masyarakat
Publisher : UPT Penelitian dan Pengabdian Kepada Masyarakat Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33795/jppkm.v7i2.40

Abstract

Training on Operation and Maintenance of Production Machines with Electronic Control for Instructors in the Industrial Electrical Engineering Study Program at SMK Turen - Kab. Malang, provides additional teaching and motivation for teachers of Electrical Engineering study programs at SMK Turen practicing Operation and Maintenance of Production Machines with Electronic Control. Besides that, it can also increase additional skills for teachers of the electrical engineering study program at the current Turen Vocational School
Workshop Penerapan Green Energy Berbasis Rooftop Solar Photovoltaic Pada UMKM Maju Lancar Kota Madiun Awan Setiawan; Rohmanita Duanaputri; Imron Ridzki; Irwan Heryanto; Rahman Azis Prasojo; Hanifiyah Darna Fidya Amaral
Jurnal Pengabdian Polinema Kepada Masyarakat Vol. 9 No. 2 (2022): Jurnal Pengabdian Polinema Kepada Masyarakat
Publisher : UPT Penelitian dan Pengabdian Kepada Masyarakat Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33795/jppkm.v9i2.167

Abstract

Indonesia adalah salah satu negara beriklim tropis serta negara yang dilalui oleh garis khatulistiwa seluruh wilayahnya mendapatkan sinar matahari yang cukup besar sepanjang tahun sehingga dapat dikembangkan energi terbarukan. Untuk meningkatkan ketersediaan energi listrik berkelanjutan secara maksimal, penggunaan PLTS rooftop skala kecil dapat menjadi solusi sebagai sumber energi listrik ketika sumber PLN padam. Dalam membuat perencanaan sistem green energy dengan PLTS perlu dilakukan analisis terlebih dahulu, dimana analisis yang dilakukan bertujuan untuk mengetahui kinerja dari sistem yang telah direncanakan agar sistem dapat bekerja secara maksimal sehingga ketersediaan energi listrik yang dibutuhkan oleh beban dapat terpenuhi. Perencanaan dan analisis tersebut juga dapat dijadikan tolak ukur untuk membuat perencanaan dengan skala besar kedepannya. Metode penelitian ini dilakukan dengan uji coba dan pengambilan data dari peralatan sistem rooftop solar photovoltaic. Pada saat pengujian dilakukan dengan menggunakan sudut kemiringan 13° dan simulasi shading pada modul photovoltaic 3x100Wp monocrystalline dengan sistem pemasangan paralel sehingga didapatkan data pengukuran dari sistem yang telah dibuat. Dari hasil uji coba dan analisis yang dilakukan bahwa kinerja dari sistem backup supply menghasilkan energi harian yang lebih besar daripada energi yang dibutuhkan beban, dengan PSH (Peak Sun Hours) selama 5 jam penyinaran. Economy feasibility dari pemasangan rooftop solar photovoltaic ditinjau dari segi techno-economic dengan menggunakan metode diperoleh Net Present Value (NPV) Rp16.383,98, Profitability Index (PI) 1,002, Internal Rate of Return (IRR) 4,53% dan payback period 20 tahun maka berdasarkan kriteria standar pemasangan sistem ini dinilai layak.
Pengaruh Tegangan Kerja Terhadap Spektrum Frekuensi Gelombang Arus Bocor Pada Isolator Keramik Awan Setiawan; Imron Ridzki; Priya Surya
JURNAL ELTEK Vol 18 No 2 (2020): ELTEK Vol 18 No 2
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (926.828 KB) | DOI: 10.33795/eltek.v18i2.255

Abstract

Penyaluran energi listrik pada jaringan PT PLN PERSERO khususnya pada jaringan distribusi sering mengalami kegagalan yang disebabkan arus bocor pada isolator keramik. Intensitas kerusakan disebabkab oleh polutan debu yang menempel pada permukaan isolator, ditambah pula dengan kelembaban udara yang ada di daerah tropis seperti Indonesia. Hal ini secara kumulatif, menyebabkan flashover pada permukaan isolator dan menyebabkan kegagalan penyaluran energy listrik pada jaringan. Pengaplikasian Silicon Rubber sebagai bahan pelapis isolator dapat mengurangi polutan debu yang menempel pada permukaan, hasil penelitian menunjukkan bahwa parameter tegangan akan berpengaruh juga pada besarnya arus bocor yang mengalir pada permukaan isolator. Semakin tinggi tegangan kerja akan memperbesar nilai RMS arus bocor yang mengalir. Terukur pada level tegangan 20 kV arus bocor yang terukur memiliki RMS sebesar 0,0432 A dengan THD sebesar 15,76 % dengan beda fasa arus bocor terhadap tegangan sumber bersifat leading hampir mendekati α = 900. Distribution of electricity in PT PLN PERSERO network, especially in distribution networks often fails due to leakage current in ceramic insulation. The intensity of damage caused by dust pollutants that are attached to the insulation surface, coupled with the humidity of the air in tropical areas such as Indonesia. This cumulatively causes flashover on the insulation surface and causes failure of electricity distribution to the network. The use of Silicon Rubber as an insulating coating can reduce the amount of dust contaminated on the surface, the results show that the voltage parameter will also affect the amount of leakage current flowing to the insulation surface. Higher working voltage will increase the current RMS leakage value. Measured at a voltage level of 20 kV the current leakage was RMS 0.0432 A with THD of 15.76%, phase difference of leakage current to leading source voltage is almost close to α = 900.
Analisis penentuan LBS sebagai upaya melokalisir daerah gangguan di penyulang Pandan Landung ULP Kebonagung PT. PLN (Persero) UP3 Malang Rohmanita Duanaputri; Awan Setiawan; Rhezal Agung Ananto
JURNAL ELTEK Vol 18 No 2 (2020): ELTEK Vol 18 No 2
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (800.918 KB) | DOI: 10.33795/eltek.v18i2.248

Abstract

Penyulang Pandan Landung merupakan penyulang dengan sistem radial. Dengan sistem radial ini, saat terjadi gangguan dapat diminimalisir dengan penempatan LBS, sedangkan untuk manuver dengan penyulang lain perlu diperhatikan dahulu beban yang dapat ditampung oleh penyulang lain dan jarak lokasi tersebut untuk manuver. Dengan melihat data gangguan yang ada saat ini, penelitian ini bertujuan untuk menganalisis penempatan LBS dalam hal melokalisir atau mempersempit daerah padam. Alternatif penempatan LBS baru dibutuhkan untuk mengurangi daerah padam. Penempatan LBS baru di Penyulang Pandan Landung yakni pada lokasi sebelum trafo R1116. LBS ini memanuver dari Penyulang Pandan Landung ke Penyulang Klayatan sehingga dapat meminimalisir daerah padam pada penyulang Pandan Landung Pandan Landung feeder is a feeder with a radial system. With this radial system, disruption can be minimized by placing LBS, while for maneuvering with other feeders, it is necessary to pay attention to the load that can be accommodated by other feeders and the distance of these locations for maneuvers. By looking at the current disturbance data, this study aims to analyze the placement of the LBS in terms of localizing or narrowing down the blackout areas. An alternative to placing new LBS is needed to reduce blackout areas. The placement of the new LBS at Pandan Landung Feeder is at the location before transformer R1116. This LBS maneuvers from the Pandan Landung feeder to the Klayatan feeder so as to minimize the area of outages in the Pandan Landung feeder. The energy lost before the maneuver is 26987.4 kWh, while when there is a maneuver the value becomes 12647.18, it can be seen that there is a decrease in the value of energy lost by 53.14%.
Analisis Manuver Penyulang Selecta untuk Menjaga Nilai Keandalan Sistem Distribusi di PT. PLN (Persero) ULP Batu Sukamdi; Awan Setiawan; Heri Sungkowo
Elposys: Jurnal Sistem Kelistrikan Vol. 9 No. 3 (2022): ELPOSYS vol.9 no.3 (2022)
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (567.871 KB) | DOI: 10.33795/elposys.v9i3.651

Abstract

PT. PLN (Persero) ULP Batu, The Selecta feeder is one of the 7 feeders in the distribution system that supplies several areas in PT. PLN (Persero) ULP Batu. In the Selecta feeder themselves, the number of error that occurred from January to November 2020 was fourteen times, with details of one time temporary error and thirteen times permanent errors. Delegating a portion of the load from feeders which got error can have an impact on feeders which are working normally. This can cause a voltage drop on the feeder for maneuvering purposes so that the distribution of electric power becomes less than optimal and requires some other loads to be temporarily transferred to other feeders. Based on the problems that occur, it is necessary to analyze the maneuver to reduce the impact of disruption on The Selecta feeder and maintain the reliability value of the distribution system at PT. PLN (Persero) ULP Batu.
SUPLAI DAYA CADANGAN MENGGUNAKAN SISTEM HYBRID Awan Setiawan; Muhammad Fahmi Hakim
Jurnal Teknik Ilmu dan Aplikasi Vol. 3 No. 2 (2022): Jurnal Teknik Ilmu dan Aplikasi
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pada perusahaan manufaktur peralatan industri, ketika terjadi pemadaman listrik PT PLN, harus menunggu proses transisi suplai daya ke genset sehingga proses produksi harus terhenti sejenak. Dengan adanya hal itu maka perlu didesain suplai daya cadangan baru yang mampu menyuplai daya dengan seketika beserta instalasinya. Suplai daya cadangan yang sesuai adalah Uniterruptible Power Supply (UPS) yang dioperasikan secara hybrid dengan genset. Langkah pertama adalah menentukan kapasitas UPS kemudian menghitung kapasitas baterai dan dilanjutkan menentukan jumlah baterai. Selanjutnya menghitung KHA penghantar beserta arus nominal MCB. Simulasi di ETAP digunakan untuk memeriksa peningkatan performa dari sistem kelistrikan pabrik menggunakan parameter tegangan. UPS yang sesuai berkapasitas 160 kVA, dimensi 560 x 940 x 1800 mm, tegangan keluaran 230/400 V, frekuensi 50-60 Hz dan faktor daya 0,9. Baterai yang digunakan berkapasitas 140 Ah, dimensi 341 x 173 x 281 mm, sejumlah 53 buah. KHA penghantar minimal adalah 80,37 A dan maksimal 161 A. Arus nominal MCB minimal 16 A dan maksimal 126 A. Berdasarkan hasil simulasi sebelum pemasangan UPS, saat suplai utama dari PLN mengalami gangguan, beban prioritas tidak mendapatkan tegangan sampai genset mensuplai energi listrik. Namun setelah pemasangan UPS beban prioritas langsung mendapatkan tegangan dari UPS yang dilanjutkan mendapat suplai dari genset. Beban prioritas yaitu beberapa mesin CNC untuk rposes produksi.
Analisis Keandalan Sistem Distribusi 20kV Pada Penyulang Pujon PT. PLN (PERSERO) ULP Batu Wijaya Kusuma; Ruwah Joto; Mochammad Mieftah; Awan Setiawan
Elposys: Jurnal Sistem Kelistrikan Vol. 9 No. 3 (2022): ELPOSYS vol.9 no.3 (2022)
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (338.759 KB) | DOI: 10.33795/elposys.v9i3.656

Abstract

At PT. PLN (Persero) ULP Batu, Pujon feeder is one of the 9 feeders in the distribution system that supplies several areas in PT. PLN (Persero) ULP Batu. At the Pujon feeder, the number of disturbances that occurred from January to November 2021 occurred twenty-two times, with details of eighteen temporary disturbances and four permanent disturbances. The number of disturbances that often occur can affect the feeder who is working normally. This can cause voltage drops and power losses, causing the flow of electric power to be less than optimal and detrimental to customers or consumers. Because it requires maneuvering so that the disturbance does not spread to all feeders and cause one feeder to experience a blackout. Based on the problems that occur, maneuver analysis is needed to reduce the impact of disturbances on the Pujon feeder and to maintain the reliability value of the distribution system at PT. PLN (Persero) ULP BATU.
Pemasangan Lampu Penerangan Jalan Berbasis Panel Surya Di Dusun Klandungan Kabupaten Malang Anang Dasa Novfowan; Awan Setiawan; Ruwahjoto Ruwahjoto; Moch. Mieftah; Sukamdi Sukamdi; Rachmat Sutjipto
Jurnal Pengabdian kepada Masyarakat Vol. 10 No. 2 (2023): JURNAL PENGABDIAN KEPADA MASYARAKAT 2023
Publisher : P3M Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33795/abdimas.v10i2.4568

Abstract

Penerangan jalan berbasis panel surya atau tenaga surya adalah inovasi yang tepat guna merupakan hasil rekayasa energi surya (matahari) yang dikonversi menjadi energi listrik, dan disimpan dalam baterai yang nantinya dijadikan sumber daya untuk penerangan jalan. Keuntungan menggunakan tenaga surya ialah tidak terpengaruh ketika suplai dari listrik PLN padam, karena energi yang digunakan adalah energi panas dari matahari serta tidak perlu lagi menarik sumber listrik dari jaringan listrik PLN. Penerangan jalan di lingkungan dusun Klandungan masih sedikit dan bersumber dari jaringan listrik PLN, sehingga dapat mengganggu kenyamanan keamanan pengguna jalan di malam hari. Latar belakang masyarakat di wilayah ini bekerja di sore sampai malam hari, sehingga penerangan jalan mutlak diperlukan ketika melewati jalan tersebut. Dengan adanya penerangan yang layak dapat memberikan kenyamanan pengguna jalan dan lingkungan sekitar.