Nia Ayu Ismaniati
Bagian Ortodonsia Fakultas Kedokteran Gigi, Universitas Indonesia, Jakarta, Indonesia

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Deformasi Slot Beberapa Produk Braket Stainless Steel Akibat Gaya Torque Pada Kawat Stainless Steel Zairina, Atika; Siregar, Erwin; Ismaniati, Nia Ayu
Majalah Kedokteran Gigi Indonesia Vol 20, No 1 (2013)
Publisher : Majalah Kedokteran Gigi Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (714.597 KB)

Abstract

Deformasi slot braket dapat mengurangi besar gaya torque  yang akan dihantarkan ke gigi dan jaringan pendukungnya. Beberapa braket stainless steel yang beredar dipasaran belum pernah diteliti kualitasnya dalam perawatan ortodonsi. Tujuan penelitian adalah untuk membandingkan besar gaya torque akibat sudut puntir 30° 45°  kawat stainless steel dan deformasi slot permanen akibat gaya torque tersebut antara kelompok merk braket (3M, Biom, Versadent, Ormco dan Shinye). Penelitian dilakukan pada lima puluh braket stainless steel edgewise dari lima kelompok merk braket (n=10) di lem ke akrilik. Masing-masing braket dilakukan pengukuran tinggi slot dengan mikroskop stereoskopi lalu dipasang ke alat uji torque yang sudah dibuat untuk penelitian ini. Setelah dilakukan uji torque, braket di ukur kembali tinggi slotnya dan dibandingkan dengan pengukuran sebelumnya untuk mengetahui adanya deformasi slot. Hasil analisis statistik menunjukkan perbedaan bermakna besar gaya torque pada sudut puntir 30° dan 45° antara Biom dan Shinye dengan Omrco. Gaya torque paling besar yaitu pada merk braket 3M (30°= 442,12 gmcm dan 45°= 567,99 gmcm), sedangkan yang terkecil adalah Biom (30°= 285,50 gmcm, 45°=361,38 gmcm). Perbedaan deformasi slot braket terjadi hampir pada semua kelompok merk braket. Deformasi slot braket hanya terjadi pada merk braket Biom (2,82 µm) dan Shinye (2,52 µm). Kesimpulan, salah satu faktor yang mempengaruhi besar gaya torque dan terjadinya deformasi slot yaitu komposisi dan proses manufaktur dari braket stainless steel. Proses manufaktur yang tidak sesuai standar dapat menyebabkan kualitas braket yang buruk. Deformasi slot permanen dalam penelitian ini terjadi pada merek braket Biom dan Shinye.ABSTRACT: Slot Deformation of Various Stainless Steel Bracket Due to Torque Expression On The Wire. Bracket slot deformation can reduce the amount of torque that will be transmitted to teeth and supporting tissues. The quality of some stainless steel brackets in the market is still questionable for orthodontic treatments. This research aims to compare the amount of torque expression due to torsion angle of 30° and 45° at the stainless steel wire and bracket slot permanent deformation caused by the torque in each examined bracket brands (3M, Biom, Versadent, Ormco and Shinye). Fifty Stainless Steel Edgewise brackets from five different brands (n = 10) were attached onto an acrylic. Each bracket slot width was measured with a stereoscopic microscope and then mounted onto a torque apparatus that had been prepared for this study. Once the torque test was done, the width of bracket slot was re-measured to determine if there was a difference from initial bracket slot width at 45°. The results of ANOVA showed significant differences in the amount of torque at torsion angle of 30°and 45° between Biom and Shinye with Omrco. The 3M transmitted the highest load (30°= 442,12 gmcm and 45°= 567,99 gmcm), while the lowest was of Biom (300  = 285,50 gmcm and 450 = 361,38 gmcm). Differences in slot bracket deformation were found virtually in all groups of bracket brands. Deformation of bracket slots occurs only in Biom (2.82 µm) and Shinye (2.52 µm). From the observation, it is concluded that one of the major factors that affect torque and deformation of bracket slot is composition and manufacturing process of the stainless steel brackets. Manufacturing process that does not meet the standard can lead to a poor quality bracket. Permanent slot deformation in this study occurrs with Biom and Shinye bracket brands.
Patients knowledge about side effects of orthodontic treatment Amalia, Mia; Anggani, Haru Setyo; Ismaniati, Nia Ayu
Padjadjaran Journal of Dentistry Vol 23, No 2 (2011): July
Publisher : Faculty of Dentistry Universitas Padjadjaran, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (216.011 KB) | DOI: 10.24198/pjd.vol23no2.14015

Abstract

Disharmonious of dental arrangement can possibly create problems for the patient, such as the masticatory function, esthetical, psychosocial, and also the increased risk of trauma and periodontal disease. These are reasons for a patient to seek orthodontic treatment. The aim of this study was to know the patient’s knowledge about the side effects possibility that they receive during orthodontic treatment. The side effects include pain experience during orthodontic treatment, the possibility of soft tissue damage, email demineralization, loss of tooth vitality, periodontal problem, root resorption, temporomandibular joint disorders, and relapse. A cross-sectional study was conducted in patients who registered at Orthodontic Department, Faculty of Dentistry, Universitas Indonesia on March-June 2009. The participants of this study were 100 patients, consist of 86 women and 14 men respectively. Twenty-seven questions about the side-effects of orthodontic treatment were used to obtain the patient’s knowledge and the result was categorized into 3 groups, good, average and poor. The result of the study showed that patient’s knowledge about the side effect of pain experience during orthodontic treatment was average and the patient’s knowledge about the possibility of soft tissue damage due to orthodontic treatment was good. However, the patient’s knowledge about the possibility of email demineralization, loss of tooth vitality, periodontal problem, root resorption, temporomandibular joint disorders and relapse due to orthodontic treatment was low.