Abdul Ro'uf
Departemen Ilmu Komputer dan Elektronika, FMIPA UGM, Yogyakarta

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Perancangan Flowmeter Ultrasonik untuk Mengukur Debit Air Pada Pipa Hidayahtullah Abdi Robhani; Abdul Ro'uf
IJEIS (Indonesian Journal of Electronics and Instrumentation Systems) Vol 8, No 1 (2018): April
Publisher : IndoCEISS in colaboration with Universitas Gadjah Mada, Indonesia.

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (730.935 KB) | DOI: 10.22146/ijeis.31774

Abstract

 Measurement of water discharge using ultrasonic wave properties ensures the stability of measured water profile because of its non-intrusive nature. In this study, a water discharge measuring device has been developed by utilizing ultrasonic wave properties to determine its speed. The device is designed using two pairs of ultrasonic transmitters and receivers at upstream and downstream positions toward the direction of the water flow. 40 kHz ultrasonic waves are generated with AD9850 DDS sinusoidal pulse generating module. The sensor data processor uses an Arduino Due microcontroller module by calculating the measured ultrasonic wave travel time difference.             Measurements were made on a 57 mm diameter pipe with flow rates varied using 25%, 50%, 75%, and 100% tap openings. The measurement resulte shows the lowest water debit calculation value of 4.42×10-4 m3/s at 25% faucet opening and highest discharge of 2.15×10-3 m3/s at 100% faucet opening with the values of coefficient of correlation and coefficient of determination on 25%, 50%, 75% and 100% faucet openings respectively 0.9715, 0.9669, 0.9604 and 0.9647 and 94.37%, 93.49%, 92 , 24%, and 93.07%.
Analisis Spesifisitas Terhadap Sensor NPK Ivan Lionel; Abdul Ro'uf; Bakhtiar Alldino
IJEIS (Indonesian Journal of Electronics and Instrumentation Systems) Vol 13, No 1 (2023): April
Publisher : IndoCEISS in colaboration with Universitas Gadjah Mada, Indonesia.

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22146/ijeis.79672

Abstract

Insufficient use of fertilizers results in non-optimal plant growth, while excessive use is wasteful and results in pollution. Sensor usage is one method for measuring the nutrient content in the soil so that the fertilization process can be carried out precisely. Accuracy, precision, and error are commonly used in analyzing sensor quality. But for chemical measurements, the specificity also needs to be analyzed. This is because the soil contains various types of nutrients, so it is necessary to know whether the readings from the sensor only come from the desired nutrients or the others. In this writing, the elements measured were N, P, and K which are nutrients needed by plants in large quantities. The sensors were tested using compounds containing N, P, or/and K elements and NPK fertilizers with different NPK ratios. Results of this study prove that the sensor is not specific as the readings are known to use the electroconductivity method as proved by the regression results between the two variables which have R² ≈ 1 correlation. In addition, the sensor also produces readings for elements/compounds that should not be read and cannot distinguish the ratio of types of compound NPK fertilizer with different types.