Ainie Khuriati R.S.
Department Of Physics, Faculty Of Science And Mathematics, Diponegoro University, Semarang

Published : 11 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 11 Documents
Search

APLIKASI PRAKTIS MODEL IDENTIFIKASI AUTOREGRESSIVE MOVING AVERAGE EXOGENOUS (ARMAX) DENGAN METODA KUADRAT TERKECIL REKURSIF Khuriati RS, Ainie
BERKALA FISIKA Vol 14, No 4 (2011): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (396.098 KB)

Abstract

AbstractEffect on variations in power heating to air temperature in the mosquito box were modelled. Transfer function for temperature ranges from 34.93 oC to 39.93 C determinedexperimentally. A step function used to excite power control and its effect on the air temperaturemeasured. From these information, the transfer function in the ARX and ARMAX form determinedand compared. An analysis of the computational results has confirmed that the ARMAX model andthe recursive least square method are superior to the ARX model and the Extended Least Square method to model the thermal behaviour in the mosquito box as indicated by the level of fitting and system stabilitytedKeywords: Identification, prediction error method, caged mosquitoes
IDENTIFIKASI DAN PERANCANGAN PENGENDALI PID MENGGUNAKAN PENDUGA ARX TERHADAP SISTEM PEMANAS UDARA DENGAN KRITERIA ISE, IAE, ITSE DAN ITAE Khuriati RS, Ainie
BERKALA FISIKA Vol 15, No 4 (2012): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (133.708 KB)

Abstract

In this paper ARX estimation methodology used to design a PID controller  for  temperature control of the air heater. The step input applied  on heating systems and logging the data   to MATLAB via a data acquisition system. The data obtained is used to identify the model ofthe process in the form of ARX estimator. PID parameters obtained by minimising the  standard errors integral(IAE, ISE, ITSE and ITAE).Keywords: PID controller, Tuning, ARX Identication, Error Integral ,and air heater
PERANCANGAN SISTEM PENGENDALIAN SUHU DENGAN PENGENDALI PID MENGGUNAKAN ESTIMASI ARX Khuriati RS, Ainie
BERKALA FISIKA Vol 15, No 1 (2012): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (288.528 KB)

Abstract

In this paper ARX estimation methodology used to design a PID controller  for  temperature control of the air heater. The step input applied on heating systems and logging the  data   toMATLAB via a data acquisition system. The data obtained is used to identify the model of the processin the form of ARX. PID parameters obtained by minimising a standard  integral errors using theleast squares  method. Then,  the results were compared with the classical methodsKeywords:  PID, Identification,  air heater
APLIKASI IMC BERBASIS STRATEGI PENALAAN PENGENDALI PID DIGITAL PADA SISTEM PEMANAS UDARA Khuriati RS, Ainie
BERKALA FISIKA Vol 15, No 2 (2012): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (420.995 KB)

Abstract

This paper investigated  an application of the methodology that was developed by Rivera, a methodology to obtain reduced-order models that satisfy the Prett-Garcıa digital PID tuningrules, using prefiltered ARX estimation as a  basis. The  method was applicated as the temperaturecontrol system on theair heater. IMC-PID controller is not only superior but it has a simple andgeneral structure such as that of a PID controller too.Keywords:  PID digital , IMC, ARX model.
KOMPUTERISASI TABEL SIFAT-SIFAT TERMODINAMIK DARI H2O, R-12, DAN R-22 (PROTAMIK) Khuriati RS, Ainie; Detika, Detika; Bawono P, Ari
BERKALA FISIKA Vol 16, No 1 (2013): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (167.148 KB)

Abstract

A computer program has been created which is used to display the thermodynamic properties (T, p, v, u, h, and s) of the working fluid of the commonly used on the power generation and processindustries,  H2O, R-12, and R-22. It  also calculates  the thermodynamic properties as function of  saturationtemperature and quality and saturation  pressure and quality. Program was developed using the thermodynamic properties of steam properties from 1967 ASME Steam Table [1] andASHRAE tables [5].Keywords: thermodynamics, properties, steam tables, refrigerant tables, quality.
Disain Peredam Suara Berbahan Dasar Sabut Kelapa dan Pengukuran Koefisien Penyerapan Bunyinya Khuriati, Ainie; Komaruddin, Eko; Nur, Muhammad
BERKALA FISIKA Vol 9, No 1 (2006): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (923.598 KB)

Abstract

research aims to determine sound absorption of absorber materials making from coconut coir composites. Absorber material have been made with different composition from coconut coir composites.             Twelve samples have been made. One of samples is natural coconut coir and the other are made from coco fiber and coco peat with certain compositions. From 12 samples, 10 samples have been tested. Absorption coefficients was measured by impedance tube method with ASTM E-1050:1990 standardization.              The experiment results show that coconut coir is up to standard for absorber material according to ISO 11654 , that is with weigthed absorption (aw) over 0,15.  Weigthed absorption of samples are, A:0,30; B:0,44;C:0,27;D:0,44; E:0,51; F:0,44; G :0,47; H:0,49; I:0,31;J:0,41.  So samples A,B,D,E,F,G,H,I and J can be classified in class-D while sample C in class-E.   Absorber materials that have been made are also compatible with marketed products.  The best composition for absorber was mixture of coco dust and coco fiber.  Improving amount of coco fiber improve maximum absorption.  Adding air cavity between samples and wall improve absorption.  Improving mass density of sample making with similar total mass of composition and similar glue improve absorption in low frequency.   Keyword: coconut coir, coco fiber, coco peat, sound absorber, impedance tube, absorption coefficient, pore.
OTOMASI SISTEM PENGENDALIAN SUHU PADA INSINERATOR UNGGUN TETAP MENGGUNAKAN PENGENDALI DUA POSISI Khuriati, Ainie
BERKALA FISIKA Vol 24, No 3 (2021): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Tungku  pembakaran  adalah    bagian  paling  penting  dari  insinerator  dimana  pembakaran berlangsung.    Pengendalian  suhu  tungku  menjadi  sangat  penting  dalam  pengoperasian  sebuah incinerator  terutama  untuk  meminimalkan  emisi.  Pengendalian  suhu  dilakukan  dengan menggunakan  pengendali  dua  posisi  tipe  T2N4S-14R,  relai,  dan  solenoida  sebagai  aktuator. Sensor  suhu  menggunakan  termokopel  tipe  K.  Bahan  bakar  menggunakan  liquid  petroleum  gas (LPG). Pengujian dilakukan dengan dua buah setpoint masing-masing sebesar 400oC dan 300oC pada ruang bakar utama. Setpoin dicapai hanya memerlukan waktu 35 detik dan 20 detik untuk masing-masing setpoint. Makalah ini difokuskan pada pengendalian suhu secara eksperimental.
RANCANG BANGUN SISTEM AKUISISI DATA KELEMBABAN DAN PENGENDALIAN SUHU PADA BOX SARANG NYAMUK MENGGUNAKAN PENGENDALI TIPE PID BERBASIS MIKROKONTROLER ATMEGA8535 UNTUK PENGAMATAN SIKLUS HIDUP NYAMUK Aedes aegypti Ibnu Sulistiyono; Ainie Khuriati RS
Youngster Physics Journal Vol 1, No 1 (2012): Youngster Physics Journal Oktober 2012
Publisher : Jurusan Fisika, Fakultas Sains dan Matematika, Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstract In this research, the PID controller (Proportional Integral Derivative) temperature control work in mosquito nest box automatically to observate life cycle of insects especially the Aedes aegypti species. This is an effort in research to looking for alternative solutions in the prevention of the disease dengue fever. Temperature and humidity SHT11 censor is used as an indicator to manage the light sandwiches intencity useful as actuators. This PID method is applicated on the microcontroller ATMEGA8535 by LCD as viewer of the results and use the computer to monitore the humadity and controls the temperatures of the insect cage settpoint box by value in the input to the processor unit (PC). The PID parameters are determined by use tunning by Ziegler Nichols reaction curve method to get the best parameter value . From the test result we get the controlling parameter  of the PID control are Kp = 51,09; Ki = 77,41; dan Kd = 8,42. Key words : PID, SHT11, Mikrokontroler Atmega8535, LCD, PC, Ziegler Nichols.
FOPDT Model Based on Experimental Data from Municipal Solid Waste Incineration Process Temperature Control in Fixed Bed Ainie Khuriati
Journal of Physics and Its Applications Vol 4, No 2 (2022): May 2022
Publisher : Diponegoro University Semarang Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jpa.v4i2.12442

Abstract

Incineration is the waste combustion at controlled high temperatures which converts waste into flue gas with the main components being CO2 and water. Temperature control aims to ensure safe combustion operation. In this study, the temperature controller uses a two-position temperature controller whose main components include two thermocouples, MAX6675, two burners, blower, Arduino, and one laptop. Temperature controllers were used to maintain the temperature in the combustion chamber and afterburner at the specified setpoint, namely 630oC and 850oC, respectively.  To test the performance of the controller, two models were made. The modeling was made using the experimental data obtained. The results show that the model and experimental results are in good agreement.
Identifikasi dan Perancangan Pengendali PID Menggunakan Penduga ARX Sistem Pemanas Udara (Halaman 1 s.d. 5) Ainie Khuriati R.S.
Jurnal Fisika Indonesia Vol 17, No 51 (2013)
Publisher : Department of Physics Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (137.325 KB) | DOI: 10.22146/jfi.13741

Abstract

Pada makalah ini digunakan metodologi estimasi Auto-Regression model with eXogeneous inputs (ARX) untuk merancang pengendali PID yang digunakan  untuk mengendalikan suhu pemanas udara. Masukan tangga dikenakan terhadap system pemanas dan data suhu udara dikirim ke MATLAB melalui system akuisisi data. Data yang diperoleh digunakan untuk mengidentifikasi model proses dalam bentuk ARX. Parameter PID diperoleh dengan meminimalkan integral galat (IAE, ISE, ITSE, dan ITAE,).