Fatimah Fatimah
Politeknik Kesehatan Kemenkes Semarang

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Optimisasi Field of View (FOV) Terhadap Kualitas Citra Pada T2WI FSE MRI Lumbal Sagital Fatimah Fatimah; Johannes Dahjono; Metria Riza Sativa
Jurnal Imejing Diagnostik (JImeD) Vol 1, No 1: January 2015
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v1i1.28

Abstract

Background : Field of view (FOV) is one of paramaters in MRI that is possibly adjusted by a radiographer. Many various adjusment of FOV that are using for lumbar MR Imaging. This study is to determine the effect of variations in the value of FOV to the image quality and anatomical information.Methods : This is a quasy experimental research. The study was conducted with 1.5 Tesla MRI. Data were collected from three volunteers with 5 variations of FOV (17cm, 22cm, 27cm, 32cm and 37cm) which is totally 15 images acquired.  Images were evaluated according to the objective evaluation of SNR and CNR  by a software in the MRI machine. Quntitative measurements of SNR were conducted on corpus vertebrae, discus intervertebralis, medulla spinalis, cerebrospinal fluid (CSF) and ligamentum flavum respectively. While CNR measurements were on CSF-corpus vertebra, CSF-discus intervertebralis, CSF-medulla spinalis, medulla spinalis-corpus vertebra, medulla spinalis-discus intervertebralis and corpus vertebra-discus intervertebralis. For conspicuity, overall image contrast and artifacts were evaluated qualitatively by three radiologists scoring on the paper sheet based on the image of corpus vertebrae, discus intervertebralis, medulla spinalis, cerebrospinal fluid, ligamentum flavum. Quantitative data of SNR and CNR value were analyzed using Linier Regression and Correlation Spearman test. While radiologists scoring were analyzed using Friedman test and cross tabulation.Results : The results showed that FOV variations affect the image qualities of T2WI FSE sagital lumbar MR Imaging. FOV variations are significantly corelate to the SNR of corpus vertebra, discus intervertebralis, medulla spinalis, CSF and ligamentum flavum. FOV variations are also significantly correlate to the CNR value  of CSF-corpus vertebra, CSF-discus intervertebralis, CSF-medulla spinalis, medulla spinalis-corpus vertebra and medulla spinalis-discus intervertebralis (p values 0,05) with positive correlation.  But there is  no correlation between FOV variations  and CNR  at the corpus vertebra-discus intervertebralis (p values = 0,109).Conclusion : Based on these results indicate that overall image and artifacts are relatively similar for all value of FOV variations.  Optimal values of FOV for T2WI FSE sagittal lumbar MR Imaging is a FOV of  27 cm.
Analisis Informasi Citra Anatomi Vaskular dengan Multi Planar Reformating (MPR) dan Maximum Intensity Projection (MIP) pada Fase Early Arteri Pemeriksaan MSCT Abdomen Ratna Istiningrum; Fatimah Fatimah; Tri Wulanhandarini
Jurnal Imejing Diagnostik (JImeD) Vol 3, No 2: July 2017
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v3i2.3192

Abstract

Background: The development in the field of image reconstruction is growing rapidly along with the development of  CT Scan. In  the early stages of  MSCT abdominal artery is usually found  various kinds of vascular abnormalities such as stenosis, aneurism and others. Post processing image techniques commonly used include MPR and MIP. The purpose of this study is to determine whether there is a difference between MPR and MIP techniques and to know which one is better between the two.Methods: This  research was  quantitative study with experimental approach. The study was conducted at Bhakti Dharma Husada Surabaya Hospital  with 15 samples by performing reconstruction on vascular anatomical image of coronal examination of  abdominal MSCT. Assessment of anatomical information data is done by 2 respondents. Data analysis was done by kappa test followed by Wilcoxon sign rank test.Result : The results showed the difference between the post-processing of MIP and MPR on the coronal stages of the early arterial phase of the abdominal MSCT examination, based on the results of  non-parametric statistical test analysis (Wilcoxon) showed  a significant value of p value = 0.001. The result of MIP mean rank value (8,46) is higher than the mean rank value of MPR (1,50), it can be known that post proceeding MIP technique on coronal phase cuts early arterial examination of abdominal MSCT produces better anatomical image information.Conclusion: On examination of abdominal MSCT in the early arterial phase should be at the time of processing the image is also done by using post-processing MIP because more clearly than the MPR.