Analisis Penolakan dan Pengulangan Citra Radiografi pada Modalitas Computed Radiography AGFA CR 35-X di Instalasi Radiologi RSUD DR. R. Goeteng Taroenadibrata Purbalingga Ikko Justian Fajarrissetyo; Panji Wibowo Nurcahyo; Asri Indah Aryani
Jurnal Imejing Diagnostik (JImeD) Vol 1, No 2: July 2015
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v1i2.3159

Abstract

Background: Reject film analysis program is a systematical process to count repeated images and determine the cause of the repeat, so it could be minimalized or banished even. This research aims to find out the reject percentage, cause of each reject percentage and the efforts to reduce it.Method: This research was a quantitative model with descriptive approach. The research has been done in February, April and May of 2016. Data were obtained from observation, documentation and interview with three radiographers. Data was analyzed by Paretto’s diagram to identify the influence of each cause.Results: In February, April and May by orders the percentage of the radiographic images reject and repeat are 4,86%, 4,65%, 6,95%. The factors of digital images reject and repeat were patient’s position (1,65%, 1,05%, 0,84%), uncorrect exposure value (1,30%, 0,98%, 1,87%), miscellaneous reasons  (0,35%, 0,38%, 0,28%), too narrow collimation  (0,26%, 0,68%, 0,47%), unsharpness (0,17%, 0,0%, 0,0%), digiscan fault (0,09%, 0,30%, 0,84%) and x-ray equipment’s fault (0,09%, 0,38%, 0,65%). Meanwhile in radiographic film factor, unwanted film  (0,61%, 0,30%, 0,67%), printer’s fault (0,35%, 0,08%, 0,95%), patient’s position (0,0%, 0,23%, 0,0%), miscellaneous  reasons  (0,0%,  0,23%,  0,19%),  too  narrow  collimation (0,0%, 0,0%, 0,90%) and unsharpness (0,0%, 0,08%, 0,0%).Conclusion: The efforts to reduce radiographic images reject and repeat were applying effective communications with patients and their family and taking notes whenever a failure occurs
Pengujian Akurasi kVp dan Linearitas pada Pesawat Sinar-X di Laboratorium Prodi Diploma III Teknik Radiodiagnostik dan Radioterapi Purwokerto Asri Indah Aryani; Indra Kartika Nugroho; Panji Wibowo Nurcahyo
Jurnal Imejing Diagnostik (JImeD) Vol 2, No 2: July 2016
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v2i2.3179

Abstract

Background: Quality control is part of the quality assurance program related to the techniques used in the monitoring the maintenance of the technical elements of the system that affect picture quality. KVp accuracy and linearity (test mAs) is one of the components which are tested on the routine test performance evaluations. The X-ray Biomedical International unit brands BRG 100 RF of Laboratory Diploma in Mechanical Radiodiagnostic and Radiotherapy Purwokerto have not been tested yet. The objectives of this study are to determine suitability output kVp accuracy and linearity that have been beeing setting at control panel X-ray unit.Methods: This research belongs to a quantitative research which was conducted in April 2016 at the Laboratory of Radiodiagnostic Diploma Engineering and Radiotherapy Purwokerto on X-ray Biomedical International unit brands BRG 100 RF. The tests carried out two stages of testing. They were the accuracy of kVp with MPD (Multi-purpose detector) tool at kVp 50, 60, 70, 80, 9 and testing linearity method using Stepwedge and Reciprocity mAs Densitometer at 55 kVp, 10 mAs with a variation of 200 mA and 100. The results was analysed based on the quality control examining contained in KMK RI No.1250, the value of deviation accuracy of kVp 6% and for linearity deviation value (mAs) ≤ ± 0.1.Result: The test results showed that there are some deviations occur repeatedly on the accuracy of kVp on the value of eksposi 50, 60, 70, 80, 90, are 0.78%, 1.31%, 1.32%, 1.63%, 2.5%, but the deviation is still within the allowable limits that does not exceed 10%. The linearity testing showes that there are differences in optical density values on the radiograph with variations mA and s which are still within the allowable limit that is ≤ ± 0.1.Conclusion: Based on the result of kVp accuracy and linearity test, the deviation value is still within the tolerance limit or still in accordance with the permissible tolerance according to KMK RI   1250 about quality control testing parameter